OPERATIONS 4-26
MCC-545C PACKET DATA RADIO
12/2000
MCC-545C COMMANDS
COMMAND
DESCRIPTION
PARAMETERS
RANGE
CR10X,RESET
Reset CR10X internal error counters to zero
†CR10X,SCALE
,type
Define sensor scaling type.
type =
545C
– data
scaled in integer
hexadecimal
units
CR10X
– data
scaled in
Campbell
Scientific
floating point
format
CR10X,SECURITY
,nnnn,
nnnn,nnnn
Enter CR10X Internal Security Codes. See CR10X
manual. If CR10X program contains security codes, this
command (with correct security codes) must precede any
other command for CR10X to respond.
nnnn = security
code
0 - 9999
CR10X,SETPTR,DATE,
TIME
Manual set up of last data pointer in the MCC-545C
DATE = mmddyy
TIME = hhmm
mm =
1 - 12
dd =
1 - 31
yy =
0 - 99
hh =
0 - 23
mm =
0 - 59
Содержание MCC-545C