Wiring Diagram- High Voltage
Multipule Operator Stations
The Jobber Plus provides for the use of two operator stations. The first operator station is wired
to terminals 15, 16 and 17.
Operator Installation of two operator stations requires a "keyed" selector switch connected to ter-
minal 26. This terminal is 12 to 24 vdc. The switch is wired so that when the switch is ON an input
current is supplied to terminal 26. 'ON' indicates that two operator stations are being used.
Depending on this switch position the message "TWO OPERATOR" or "ONE OPERATOR" is
displayed on the bottom line of the LCD.
For safety reasons the operator stations should be wired so that when TWO stations are selected
an indicator light on the second operator stations is lit. A CAUTION label should be placed on the
second operator station warning that if the light is not 'ON' the station is disabled and unsafe!
#50-51-52