![Metallkraft ULMS 420 Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/metallkraft/ulms-420/ulms-420_instruction-manual_1777194014.webp)
14
ULMS-Series | Version 2.04
Operation
7.6 Connection of the clamping device
Model ULMS 420 und ULMS 500
Pneumatic hold-down clamps automatically clamp the
workpiece as soon as the protective cover is closed. It is
crucial to hold the material to be machined in place while
cutting.
7.7 Compressed air connection
Step 1: Connect the compressed air supply line to the
connection on the rear of the machine.
Fig. 14: Compressed air connection (left) and maintenance unit with
pressure gauge (right)
Step 2: Set the desired working pressure (6 - 8 bar) on the
compressed air regulator.
8
Operation
8.1 Settings and commissioning
Connecting to the mains
WARNING!
Position the hold-down clamps so that they do not
come into contact with the saw blade
WARNING!
Danger due to insufficient qualifica-
tion of persons!
Insufficiently qualified personnel can not assess the
risks involved in repairing the equipment and expose
themselves and others to the risk of serious injury.
WARNING!
Risk of life!
There is danger to life for the operator and other per-
sons if they do not adhere to the following rules.
- The operator may not work while under the influ-
ence of alcohol, drugs or medication.
- The operator must not work when he is tired or suf-
fering from concentration-impairing illnesses.
- The Automatic light alloy metal-cutting saw may
only be operated by one person. Other persons
must keep away from the work area during opera-
tion.
DANGER!
Risk of injury!
When working on the Automatic light alloy metal-cut-
ting saw
- is to wear tight-fitting clothing.
- no jewelry may be worn.
- Do not wear scarves, ties or similar.
- For long hair, a hairnet must be worn.
DANGER!
Risk of injury!
Never reach into the openings (for example, bet-
ween saw blade and housing) on the machine, as
long as it is connected to the power supply!
Wear ear protection!
Wear safety glasses!
Wear safety shoes!
Wear protective clothing!
DANGER!
All work on the electrical installation may only be car-
ried out by a qualified electrician.
NOTE!
Before commissioning, the following must be obser-
ved.
- The mains voltage must correspond to the voltage
specifications on the rating plate.
- The main switch must be set to "0".
- The safety devices as well as the protective covers
must be functional.
Содержание ULMS 420
Страница 1: ...Instruction Manual ULMS 420 Automatic light alloy metal cutting saw ULMS 500 ULMS 420...
Страница 22: ...22 ULMS Series Version 2 04 Spare parts Spare parts drawing 2 ULMS 420 Fig 24 Spare parts drawing 2 ULMS 420...
Страница 23: ...Spare parts ULMS Series Version 2 04 23 Spare parts drawing 3 ULMS 420 Fig 25 Spare parts drawing 3 ULMS 420...
Страница 24: ...24 ULMS Series Version 2 04 Spare parts Spare parts drawing 4 ULMS 420 Fig 26 Spare parts drawing 4 ULMS 420...
Страница 26: ...26 ULMS Series Version 2 04 Spare parts Spare parts drawing 7 ULMS 420 Fig 29 Spare parts drawing 7 ULMS 420...
Страница 28: ...28 ULMS Series Version 2 04 Spare parts Spare parts drawing 2 ULMS 500 Fig 31 Spare parts drawing 2 ULMS 500...
Страница 29: ...Spare parts ULMS Series Version 2 04 29 Spare parts drawing 3 ULMS 500 Fig 32 Spare parts drawing 3 ULMS 500...
Страница 31: ...Spare parts ULMS Series Version 2 04 31 Spare parts drawing 6 ULMS 500 Fig 35 Spare parts drawing 6 ULMS 500...
Страница 32: ...32 ULMS Series Version 2 04 Spare parts Spare parts drawing 7 ULMS 500 Fig 36 Spare parts drawing 7 ULMS 500...
Страница 35: ...Electrical circuit diagram ULMS Series Version 2 04 35 Fig 39 Electrical circuit diagram ULMS 420 ULMS 500...
Страница 39: ...Notes ULMS Series Version 2 04 39 16 Notes...
Страница 40: ...www metallkraft de...