Tips when using the boiler
(USER)
the boiler can be operated by two adults who have familiried themselves with the manual
the presence of unsupervised children in the boiler room, or allowing them to operate the
boiler is forbidden.
ensure that the boiler is switched off during any works with flammable materials that emimt
flammable gases or fumes e.g glueing, painting etc.)
turn off the boiler before clearing out the exhaust carbon from the retort, gutter etc.( „OFF”
position)
turn off the boiler before stoking the boiler („OFF position)
do not use flammable liquids for igniting the boiler, the boiler ignites automatically (ignition)
turn off the boiler before cleaning
do not overheat the boiler
do not place any flammable material in the close vicinity of the boiler
during ash removal, any flammable materials should be kept at a distance of 150 cm from
the boiler
the ash should be placed in heat resistant containers with a lid
if the boiler operates at the temperature lower that 60C, the steel exchanger may „sweat”
and cause corrosion that shorten the boiler life span. That is why the minimum operation
temperature of the boiler should be 60C
after the heating season is over, the boiler and the smoke duct must be thoroughly cleaned
the boiler room should be kept tidy and dry
ATTENTION!
The boiler is not meant to be operated by persons of lowered mental or physical
independence or by persons with no experience or limited knowledge about the
product if they are not supervised or instructed by the person responsible for their
safety.
ATTENTION!
Any tampering with the boiler electronic system or boiler construction is forbidden.
24.
Boiler maintenece and cleaning
(USER)
ATTENTION!
Clean the boiler only when it is disconnected from the power supply.
In order to save fuel, the burner chamber as well as the convection channels must be kept clean.
The walls and the grates in the burner chamber should be cleaned through the charger and burner
doors. The boiler exchanger should also be cleaned regularly.
The convection channels and the flue should be cleaned through cleaning hatch on the boiler
flue or at the bottom in the side wall. It should be carried out with expendable metal brushes. The
boiler should be cleaned during the idle period, preferably every 100 hours. A thorough cleaning of
the boiler should be done monthly.
If the fuel is of low quality, cleaning should be done more often.
25.
Istruction for utilising the boiler
(USER)
Before scrapping the boiler, all the electronic elements should be removed. They should be
disposed of according to the 2002/96/WE Electric and Electronic Equipment. In order to dispose of
the electronic elements you should contact the manufacturer.
The steel elements the boiler is made from should be scrapped in the dedicated locations (scrap
yards).
ATTENTION!
The boiler and its elements should not be disposed of toghether with other waste.
26.
Spare parts list
(USER/INSTALLER)
Tab. 26.1 Spare parts
Spare parts
Article
Sensors
Sensors
Temperature sensors for GOLD
Boiler sensor
Feeder sensor
Return sensor
Central Heating Sensor
Hot Tap Water Sensor
Outside sensor
Fumes sensor
Photo sensor
Temperature sensor for PLATINUM
Boiler sensor
Feeder sensor
Return sensor
Central Heating sensor
Controllers
GOLD Regulator
PLATINUM Regulator
STB Thermal protection
Ignition
Ignition 700W
Sensor
Lambda sensor set