24
c) First boiler start-up.
If all of the above steps have been performed correctly, first boiler start-up can be commenced.
Extinguishing the boiler
If you plan a longer idle period for the boiler, set the control panel in the „OFF” mode.
Re-commencing the boiler if the boiler had been stopped due to lack of fuel.
remove the carbon deposit from the burner
feed the fuel into the bin
on the control panel, set the „OFF” mode
feed the fuel into the burner with the „TEST” manual fuel stoking feature,
feed the fuel until granulate is visible at the top of the burner
set the „ON” mode on the control panel, flame should appear after few minutes
if there is no ignition, set fire by using traditional grill ignition
set the blower to „TEST”
after starting fire, set the „ON” mode on the control panel.
Automatic commencing the boiler after replacing the safety clutch fuse:
remove the carbon deposit from the burner
turn the screw left and right and check if there are no „foreign bodies” e.g. stone, metal rod.
If such are present, rmove them and put on the pin
feed the fuel into the bin
on the control panel, set the „OFF” mode
feed the fuel into the burner with the „TEST” manual fuel stoking feature,
feed the fuel until granulate is visible at the top of the burner
set the „ON” mode on the control panel, flame should appear after few minutes
if there is no ignition, set fire by using traditional grill ignition or wood
set the blower to „TEST”
after starting fire, set the „ON” mode on the control panel.
ATTENTION!
Remember to close the feeder cover tightly.
ATTENTION!
Do not stand in front of the boiler when opening the boiler door as you may run the
risk of getting burn.
ATTENTION!
If the boiler is equipped with a Lambda sensor, set its parameters with a fumes
analyser during setting the blower for the following boiler powers.
22.
Recommended boiler power settings
(USER)
To obtain the correct, fault-free and efficient operation of the boiler, the boiler should operate
at 80% of its nominal power and temperature of 60C. It is also suggested to install a mixing valve.
Tab. 22.1 Suggested settings of GOLD and PLATINUM controller for work
with chute burner – pellet fuel
Power
14
16
19
20
28
34
38
50
75 100 150 200
Parameter
Feeder's anti-blockade
5
5
5
5
5
5
5
5
5
5
5
5
Feeder cycle (ON+OFF)
20
20
20
20
20
20
20
20
20
20
20
20
Feeding in cycle-ON
22
25
29
31
43
53
58
28
42
56
53
70
Initial stoking
25
25
25
25
25
25
25
15
15
15
15
15
Ignition
0
0
0
0
0
0
0
0
0
0
0
0
Ignitor
3
3
3
3
3
3
3
3
3
4
4
4
Fire test
3
3
3
3
3
3
3
2
3
3
2
2
Initial power
60
60
60
60
60
60
60
60
60
60
60
60
Burn out
2
2
2
2
2
2
2
2
2
2
2
2
Boiler power (kW)
14
16
19
20
28
34
38
50
75 100 150 200
Blower 100%
12
12
12
12
12
15
15
15
20
25
70
5
Blower 80%
11
11
11
11
11
13
13
13
18
22
60
65
Blower 60%
10
10
10
10
10
11
11
11
16
20
50
55
Blower 40%
9
9
9
9
9
9
9
9
14
18
40
45
Blower 20%
8
8
8
8
8
8
8
8
12
16
30
35
Starting power
9
9
9
9
9
9
9
9
9
9
12
12
Burn out
12
12
12
12
12
12
12
12
12
12
12
12
Sustain power
12
12
12
12
12
12
12
12
12
12
12
12
ATTENTION!
The controller settings can be regulated depending on the variety of the existing
central heating systems, heating requirements of the bulding and calorific value of
the fuel. The boiler parameters are set by the user and it is not serviced by the
company.