Controlling blinds
• raising/lowering (> 0.5 s)
• up/down in steps (< 0.5 s)
Global blind control
|
Global control via PlusLink is possible in combi-
nation with the central unit insert and the display
timer module.
Example of global raising/lowering and gradual up/
down of 1-4 PL lines
Following activation of the push-buttons and of the
module on the central unit insert, all loads in the PL lines
are controlled together.
Arrow buttons with push-button function:
• Long push-button action (> 0.5 s): raising/lowering
• Short push-button action (< 0.5 s): up/down gradually
A
Module on central unit insert
B
Blind control insert
Switching load on/off
In combination with 1-gang / 2-gang insert
|
In combination with a 2-gang insert both channels
are switched together.
Display of the status arrow in the display only re-
fers to channel 1.
Blind control
Light control
< 0,5 s
>
> 0,5 s
< 0,5 s
> 0,5 s
Menu
OK
Man
A
B
B
PL4 PL3 PL2
PL1
< 0,5 s
>
> 0,5 s
< 0,5 s
> 0,5 s
Menu
OK
Man
< 0,5 s
Menu
OK
Man
Dimming load
In combination with 1-gang / 2-gang insert
|
In combination with a 2-gang insert both channels
are dimmed together.
Display of the status arrow only refers to channel
1.
Global light control
|
Global control via PlusLink is possible in combi-
nation with the central unit insert and the display
timer module.
Example of globally switching on/off and dimming
the 1-4 PL lines
Following activation of the push-buttons and of the
module on the central unit insert, all loads in the PL lines
are controlled together:
Arrow buttons with push-button function
• Short push-button action (< 0.5 s): turn on/off
• Long push-button action (> 0.5 s): dimming
A
Module on central unit insert
B
Inserts for switching and dimming (see function
overview)
|
Global scenes are possible via the arrow buttons
in combination with the central unit insert and the
display timer module (from version 1.5).
Arrow buttons with scene function:
• Short push-button action (< 0.5 s): Retrieve scene 1/2
Global blind and light scenes
Retrieve scene 1
Retrieve scene 2
> 0,5 s
Menu
OK
Man
A
B
B
B
PL4 PL3 PL2
PL1
< 0,5 s
< 0,5 s
>
> 0,5 s
>
> 0,5 s
Menu
OK
Man
< 0,5 s
Menu
OK
Man
• Central unit insert or side controller Plus, 1-gang/2-
gang:
switching, dimming, controlling blinds and retrieving
scenes
• Mechanical push-button/double push-button
• Sensor int sensors
"FAIL" flashes on the display, all LEDs flash red.
• Module was plugged onto an insert that differs in func-
tionality from the previous one.
– Reset module to default settings.
The blind or lighting does not react to a set switch-
ing time.
• PlusLink commands deactivate the switching times.
– The panic scene is being executed.
– Wind alarm is active.
– Window / door with magnetic contact is open.
– Sun/twilight sensor is performing sun protection
function.
– All other PlusLink commands and switching times
are performed when levels 1 - 4 are not carried out.
• The module is in manual mode.
While the astro function is activated, the blind and
the lighting activities deviate significantly from the
actual times of sunrise or sunset.
• Date/time settings and astro time shift are not set cor-
rectly.
• Switching between summer/winter time is not activat-
ed.
The sun protection function is not performed.
• The brightness threshold is set too high.
– Reduce brightness threshold in advanced menu.
• Blind is not in the top limit position. Any manual actua-
tion deactivates the sun protection function.
– Bring blind into top position with a long push of the
button and wait for max. 2 min. (running time).
• Wind alarm is active and disables lowering of the
blind. The wind symbol is shown on the display.
– Await wind alarm.
• The sun/twilight sensor is in the shade and cannot de-
tect sunlight.
– Install sun/twilight sensor on the window in such a
way that sunlight is reliably detected.
– Raise the blind position for the sun protection func-
tion in the advanced menu.
• The window / door is open. The magnetic contact dis-
ables lowering of the blind.
– Close window / door.
• The panic scene is being executed.
• The module is in manual mode.
When the window / door with magnetic contact is
open, the blind moves up or down.
• Wind alarm is active, causing the blind to be raised to
top position.
– Await wind alarm.
– Change the blind's behaviour for wind alarm in the
menu.
Controlling loads from another location
via PlusLink
What should I do if there is a problem?