background image

V5

75

5-

58

1-

02

 0

1/1

5

7

Example of blind control:

Set -32 minutes for the location Cologne. This has the 

consequence that the blinds are lowered in accordance 

with the later sunset time (32 minutes later than Görlitz).

Random function

This enables you to give any external observer the im-

pression that you are at home. The random function uses 

an integrated random generator to vary the times you set 

by between 0 minutes and 30 minutes every day.

A

Set UP time 7:30 a.m.

B

Set DOWN time 6:30 p.m.

C

Random range 0-30 minutes

You can activate the random function separately for each 

switching time (see "Set switching times").

Additional functions for blind control

Individual blind movement time

The module is preset at the factory so that the blind takes 

2 min. to be lowered (and, where necessary, stops auto-

matically when the lower limit position is reached). You 

can adjust this time freely between 30 seconds and 3 

minutes. This means scenes can be performed faster.

(see "Setting individual blind movement time").

Sun protection function

The sun protection function is activated as soon as the 

brightness at the window measured by the sun/twilight 

sensor exceeds the set limit value for 2 minutes. The 

blind is lowered to below the sensor and moves back up 

again for the movement time set. The time the blind 

moves back up needs to be set so that the blind stops 

just above the sensor. If the measured brightness falls 

below the limit value for 15 minutes, the blind is raised 

again.
The brightness limit value and the raising time can be set 

in the advanced menu of the module (see "Setting the 

brightness threshold for sun protection function" and 

"Setting the blind position for sun protection function").

1. The sun/twilight sensor measures the brightness. The 

limit value is exceeded.

2. The blind is lowered. The sensor is now in the shade, 

the blind stops below the sensor.

3. Blind is raised for the duration set and stops above the 

sensor. 

|

Manual operation of the module deactivates the 

sun protection function. The sun symbol is not 

visible on the display.
The sun protection function is only active when 

the blind is completely raised.

18.00

0

7.00

8.00

19.00

0...30 min

0...30 min

A

B

C

C

2

1

3

Disabling blind movement with magnetic contact

(Only in combination with blind control insert, brightness 

sensor interface flush-mounted and magnetic contact)
Raising/lowering the blind via PlusLink commands or via 

switching times of the display timer module is disabled 

by a magnetic contact when the window or door is open.
Manual operation is still possible with the   and   push-

buttons.

A

Magnetic contact

½

CAUTION

Risk of burglary! 

Please bear in mind that the blind will not close 

while the window/door is open when using the 

magnetic contact.

Wind alarm

In order to protect blinds or awnings from damage 

caused by strong wind, you can set a blind behaviour for 

wind alarm.
As soon as the wind speed set on the wind sensor has 

been steadily exceeded for a period of at least 15 sec-

onds, the blind reacts according to the set behaviour 

(see "Setting the behaviour for wind alarm"). There are 

three possible settings:
• Blind is lowered in the event of wind alarm (standard 

setting).

• Blind is raised in the event of wind alarm.
• Blind does not react to wind alarm.
During this time and until the wind speed drops, lowering 

and raising the blind via PL or module switching times is 

disabled. Manual operation is still possible with the   

and   push-buttons. The blind is not automatically low-

ered or raised after the wind alarm is over.

1. Blind is partially lowered.
2. The wind is increasing and exceeds the limit value. Af-

ter 15 s the sensor interface triggers a wind alarm via 

the PL.

3. The blind behaves according to its settings.

Evaluating DCF timer

(Only in combination with brightness sensor with wind 

sensor interface and DCF)
The module can receive a DCF time signal via a sensor 

interface connected to the PlusLink. The DCF time sig-

nal is sent to the module via PL once a day (approx. at 2 

o'clock in the morning). The module uses this to auto-

matically set the current date and time.
With the DCF time signal the changeover from summer 

to winter time occurs automatically.

Response to mains voltage failure and 

recovery / power reserve

In the event of mains voltage failure the display goes out. 

The following menu settings are saved permanently:
• Switching times
• Arrow button function
• Scenes
• Blind position for the sun protection function
• Display settings
• Operating  mode

Menu

OK

Man

A

1

3

2

15 s

The set time and date are saved for at least 6 hours 

thanks to the power reserve (no batteries required).
After mains voltage recovery the next switching time is 

carried out. Missed switching times are not carried out.

Deactivate the time and PlusLink control

Press the 

[Man]

 push-button to switch the module to 

manual mode and deactivate the control via set switch-

ing times and via PlusLink commands. Loads can then 

only be controlled manually with the   and   push-but-

tons.

|

Exceptions:
• The panic scene is being executed.
• In combination with a blind control insert, the 

module reacts to sensor values via PlusLink 

and controls the blind accordingly.

To switch back, press the 

[Man]

 push-button for 2 s.

After switching to manual mode, "Auto" disappears from 

the display and the LED next to the 

[Man]

 push-button 

lights up red.

Basic functions

Status LEDs for the module 

Resetting to default settings

Operating the module

Operation

Status feedback

– green LED briefly 

lights up upon ac-

tuation

– Arrow  symbol  ap-

pears when load 

is activated (light 

on / blind is 

raised)

– green LED briefly 

lights up upon ac-

tuation

– Arrow  symbol  ap-

pears when load 

is activated (blind 

is lowered)

Operation

Status feedback

all LEDs briefly flash 

red and all display 

symbols appear

2 s

Menu

OK

Man

Menu

OK

Man

Menu

OK

Man

10 s

Menu

OK

Man

Содержание MEG5755-03 series

Страница 1: ...witchover Individually adjustable blind movement time Adjustable brightness threshold for sun protection function Adjustable response for wind alarm Adjustable display brightness Automatic deactivation of display lighting can be se lected from version 1 5 Power reserve of at least 6 hours in the event of a pow er failure Reset restore default settings Table of Content Getting to know the display t...

Страница 2: ...g the time Setting the day month and year Switching time 2 Sun protection function activated Setting the brightness threshold Wind alarm is executed Setting the behaviour for wind alarm Switching between summer and winter time DCF timer is evaluated Mounting the module B C A Initialising the module After plugging the module onto the insert for the first time information on the module type and modu...

Страница 3: ...ion for sun protection function Set response for wind alarm Set display brightness Set automatic deactivation of display lighting The following push buttons are used to operate the menu With a long press of Menu the menu for setting the time and switching time appears after 2 s To open the advanced menu hold the Menu push button down If you do not press any push button in the menu for more than 2 ...

Страница 4: ...sh button or 7 Confirm setting with OK The time display flashes 8 Set switching time with or push button 9 Confirm setting with OK The operating mode display flashes 0 Select operating mode with or push button and confirm with OK The time display flashes Set second switching time with or push but ton Confirm setting with OK If you press the Man push button a switching time set previously appears T...

Страница 5: ...1 display appears 3 Confirm setting with OK The no display appears 4 Select save option yes with push button or 5 Confirm setting with OK Light scene All lamps are switched off briefly and then back on again to indicate that the saving procedure has been successful Then the lamps adopt the saved brightness value Blind scene The blinds are lowered and raised by one step to indicate that the saving ...

Страница 6: ...astro function separately for each switching time see Set switching times If the activated astro function has calculated that it will still be dark outside at the set switching time e g Raise blind at 6 30 a m it will not raise the blind until the sun rises Likewise the blind will be lowered at sunset if the acti vated astro function has calculated that it will be dark be fore the set switching ti...

Страница 7: ...damage caused by strong wind you can set a blind behaviour for wind alarm As soon as the wind speed set on the wind sensor has been steadily exceeded for a period of at least 15 sec onds the blind reacts according to the set behaviour see Setting the behaviour for wind alarm There are three possible settings Blind is lowered in the event of wind alarm standard setting Blind is raised in the event ...

Страница 8: ...L2 PL1 0 5 s 0 5 s 0 5 s 0 5 s Menu OK Man 0 5 s Menu OK Man Central unit insert or side controller Plus 1 gang 2 gang switching dimming controlling blinds and retrieving scenes Mechanical push button double push button Sensor interface sensors FAIL flashes on the display all LEDs flash red Module was plugged onto an insert that differs in func tionality from the previous one Reset module to defau...

Страница 9: ...per PL line 2 switching cycles day Functions Drift 1 s day Power reserve 6 hours no battery required Connectable ran dom generator 0 30 minutes Astro function Astro time shift 2 hours Standard blind movement time 2 minutes Display elements 5 LED LCD display Operating elements Menu push button Manual push button OK push button arrow push button UP arrow push button DOWN Connection module interface ...

Отзывы: