Electronic Timer
(
10, 20, 30, 60 minutes)
Cat No. ACT6Ø (Lighted)
1000W Incandescent – 20A-120VAC, 60Hz Inductive
1 hp-120VAC, 60Hz-UL – 3/4 hp-120VAC, 60Hz-CSA
INSTALLATION INSTRUCTIONS
WARNINGS AND CAUTIONS:
• To be installed and/or used in accordance with appropriate electrical codes and regulations.
• If you are unsure about any part of these instructions, consult a qualifi ed electrician.
• Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL.
Step 1
WARNING:
TO AVOID FIRE, SHOCK, OR DEATH; TURN
OFF POWER
at circuit breaker or fuse and test that power is
off before wiring!
/.
/&&
/.
/&&
/.
/&&
/.
/&&
/.
/&&
/.
/&&
/.
/&&
/.
/&&
/.
/&&
/.
/&&
/.
/&&
/.
/&&
2
4
3
1
Single Pole
1.
Line (Hot)
2.
Neutral
3.
Ground
4.
Load
DI-000-ACT60-00A-X0
INSTALLING YOUR TIMER
NOTE:
Use check boxes when Steps are completed.
Identifying your wiring application (most common):
NOTE:
If wiring in the wall box does not resemble this
confi guration, consult a qualifi ed electrician.
Preparing and connecting wires:
Strip Gage
(measure bare wire here)
5/8"
(1.6 cm)
Cut
(if necessary)
For non-standard wiring applications, refer
to Wire Nut and Conductor Size Chart
1 - #12 w/ 1 to 3 #14, #16 or #18
2 - #12 w/ 1 or 2 #16 or #18
1 - #14 w/ 1 to 4 #16 or #18
2 - #14 w/ 1 to 3 #16 or #18
WIRE NUT / # OF COND.
COMBINATION CHART
• Pull off pre-cut insulation from timer leads.
• Make sure the ends of the wires from the wall box are
straight (cut if necessary).
• Remove 5/8" (1.6 cm) of insulation from each wire in the
wall box as shown.
Important Notice for Installer
To achieve proper aesthetic installation of the Acenti products,
the wall surface surrounding the wall box opening must be fairly
fl at and free of irregularities. The wall box must be level and
recessed or fl ush to the wall surface. The Acenti installation
system allows for adjustments that will correct minor fl aws that
may be present in the installation area.
This device must be installed with the Acenti
TM
Alignment Plate.
The Alignment Plate is packaged with the Acenti
TM
Wallplate,
which is sold separately from this device.
The Alignment Plate will function properly only if it is mounted to
a fl at wall surface as described above.
• Leviton recommends to temporarily position the Alignment
Plate prior to wiring the device. If the wall box wires extend at
least 6 inches out of the wall box, it is also possible to install
the Alignment Plate after the device has been wired
(refer to
Wallplate instruction sheet).
• The Alignment Plate must be installed with the tab towards
the bottom.
• Leviton recommends the following methods to
temporarily
hold the Alignment Plate – use of device mounting screw,
use of wall box wires, or use of electrical tape
(refer to the
following fi gures):
Installing your Alignment Plate:
Alignment Plate Held
By Mounting Screw
TOP
A
Mounting
Screw
Alignment
Plate
C
TOP
Alignment Plate Held
By Tape
Electrical
Tape
B
TOP
Step 2
Step 3
Step 4
Step 4 cont’d
Alignment Plate Held
By Wires
Slotted/Phillips Screwdriver
Electrical Tape
Pliers
Pencil
Cutters
Ruler
Tools needed to install your Timer:
MULTI-DEVICE APPLICATION:
NOTE:
You only need to remove side sections if installing with other
timers/dimmers or if it does not fi t in wall box – not when installing with
mechanical switches.
If installing Timer in a single device application, proceed with the
INSTALLING YOUR TIMER
section. If installing Timer in a multi-device
application, proceed as follows:
Installing Timer by itself or with other devices:
Remove
all inner
side
sections
Do not
remove
outer
side
sections
Bend back and
forth to remove
side section