23
Replacing the Carriage
1.
Remove carriage stopper [47].
4.
Align fixed rollers [37] with c-channels [51], then adjust floating
rollers [38] as necessary before guiding carriage [15] into rails [14].
CAUTION:
We strongly advise that two people perform this
operation to prevent damaging rollers or the spring holder [33].
Ensure the carriage is raised above the pulley post receptacle [23]
before attempting to set carriage into the rails.
2.
Wipe inside of aluminum rails (c-channels) [51] with a damp
cloth using water only to remove dust or dirt. Spray onto cloth
first. Avoid spraying liquid directly onto surfaces, rollers or rails.
Insert carriage stopper [47] in one of six positions.
3.
Ensure pulley posts [27] have been removed. Carefully turn
carriage [15] over. Ensure rollers are secure and do not come in
contact with the floor.
NOTE:
Requires two people.
5. SPX MAX:
Insert pulley posts [27] into receptacles [23] at back
of Reformer and tighten star knobs [36]. Ensure eyehooks [52] on
top of pulley posts are parallel to rails.
V2 MAX & V2 MAX REHAB:
Pull out plunger button [50] and
adjust pulley posts [27] to desired height. Release the button and
lock the pulley post in place. Ensure the plunger has reset fully
into the slot. Align top of pulleys with top of shoulder rests.
Required Tool
Universal Assembly Tool
(supplied)