Merlin XLR8 MGS524 Скачать руководство пользователя страница 19

19

The gate opener doesn’t respond at all; no LED is

on. 

Possibly power failure. 

1. Check conductor and zero conductor. 

2. Check house fusing. 

Check whether the radio module is   

seated correctly.

Immediately after the gate has started moving, it

stops and reverses. 

Obstacle in area of gate. 

Gate rough running (consult dealer)

Check gate area for objects 

Check photocells

Reprogram travel distance

Gate can only be opened

Photocell blocks

Function and connection must be

checked

“Timer to close” doesn’t work.

Only works if the 2-cable photocell 770,771

or 772 installed. 

The control board does not work any more using

the transmitter, only with the switch and even then

only as long as a button is pressed and kept

pressed. 

Photocell, a contact strip or the emergency

stop disables the control board.

Only one photocell was connected for OPEN

At least 1 pair of photocells active in

OPEN or CLOSED must be connected

The gate opener doesn’t respond at all, although

the controller has been connected (LEDs are on). 

1. Remote control not programmed. 

2. LEDs indicate a fault. 

3. Photocell connected incorrectly. 

4. Motor terminal possibly not connected 

properly. 

1. Programming remote control. 

2. Find and rectify fault(s) (see description of 

diagnostic LEDs). 

3. Check photocell connection / programming. 

4. Check terminals and connections. 

The remote control’s range is too short. 

The installation of an external aerial is recommended as the controller with the short cable

aerial is located either behind the post or near ground level in most cases. The optimum

location of the aerial is as high as possible in all cases. An appropriate aerial with installation

kit can be obtained from Chamberlain as an accessory. 

The gate must follow a slope. 

Not recommended! Change gate! The gate can move in an uncontrolled (dangerous) manner if

the gate opener has been released. A stronger force is needed in the upwards direction of the

slope and then, in the opposite direction, the gate opener’s force is too strong. 

FAQs

Pressing P1, P2 and P3 does not show any reaction

Jumper “RADIO” must be removed.

Check whether the radio module is

seated correctly.

Travel distance can’t be programmed.

1. Jumper setting not correct

2. See Diagnostic LED

3. Interferences in wiring of photocells, switch  

or safety edge  

4. Gate moves for 1 second only and stops 

without reversal during programming

5. Magnetic limit switch

1: Follow the instructions of “initial operation” 

closely

3: Remove for checking, then re-program 

travel distance

4: Check RPM sensor/Encoder on control 

board 

5: Install magnetic limit switch properly

The operator sometimes moves slowly 

Power failure

Common procedure. After power failure the

operator performs a selftest. Depending on

the operator model this can take a few

seconds or a complete cycle. Do not interrupt

this test via remote control or switch,

otherwise the limits may change. If this is the

case reprogram travel distance using P1.

Control board does not work

Travel distance not programmed

Program travel distance. See initial

operation / diagnosis LED

Control board does not work with transmitter

1. Transmitter not programmed

2. Photocells block

3. Jumper “RADIO”

1.Program transmitter

2.Check photocells, check diagnostic LEDs

3. Jumper “RADIO” must be plugged.

Gate doesn’t open completely

Gate heavy / rough running

Re-program travel distance

Consult dealer/specialist

Limit switches OPEN and CLOSED not correctly

indicated

Incorrect programming

During programming the limit switch  OPEN

must be reached using P1, then limit switch

CLOSED. Switching motor cables is not

required.

Gate opens instead of closing automatically

(timer to close activated)

Incorrect programming

Repeat programming as described in these

instructions

Содержание XLR8 MGS524

Страница 1: ...Professional Installation ONLY For level gradient installations ONLY Chamberlain Australia Pty Ltd PO Box 1446 Lane Cove NSW 1595 Phone toll free 1800 638 234 Chamberlain New Zealand Ltd PO Box 100 2...

Страница 2: ...ries as it closes After the installation a final test of the full function of the system and the full function of the safety devices must be done The full protection against potential squeeze or entra...

Страница 3: ...oad circuit When this occurs the unit will cease operations until such time as the motor cools Gate size When calculating the gates weight allow for the gate s length a light weight long gate long 5m...

Страница 4: ...t the exit point for the conduit is on the correct side of the base plate in relation to the motor The plate has two recesses ensure that the conduit exits to the rear of the motor this will facilitat...

Страница 5: ...el including the start and stop limits 1 2mm clearance between drive and rack Mounting the Motor Hand tighten one of the nuts provided onto each of the four posts tighten to about 15mm from the base o...

Страница 6: ...using the bolt and nylex nut provided Installing the magnet and bracket for nylon rack Identify your start and stop limit Fit the bracket over the rack and tighten the screws Install the start and st...

Страница 7: ...5m 1 2 3 4 5 2 3 INSTALLATION OF CONTROL BOARD The CB202 control board was designed for installation in a special covering under the housing of the sliding gate drive The installation of the electrica...

Страница 8: ...in 0 5mm Terminals The terminal blocks on the controller can be removed pull to facilitate a convenient wiring and are pushed back only while installing the controller Even if a terminal strip is not...

Страница 9: ...Rolling Code feasible frequencies 433 MHz The motor control unit is a highly modern electronic unit controlled by a microprocessor It has all wiring facilities and functions required for safe operati...

Страница 10: ...tor red cable 24 V 150 mA flashing light accessory Key symbol keyswitch COM negative pole PHOTO2 photocells 2 accessory PHOTO1 photocells 1 accessory COM negative pole STOP stop switch or 8 2 kOhms sa...

Страница 11: ...section 0 5 mm2 or more Also see STOP 8 2kOHM under Jumper Settings ANTENNA OPTIONAL MODEL ANT4X 1LM The control board is supplied with a wire antenna as standard An external antenna accessory can be...

Страница 12: ...OBSTACLE SPEED 1 SPEED 2 RADIO PHO 3 LEARN DGN LIGHT CONTACT PED COM STOP OPEN PED Model CM475 8 2 open ffnen ouvrir open open ffnen ouvrir open close schliessen fermer sluiten close schliessen fermer...

Страница 13: ...ust be removed and replaced by the switch or a switch circuit OPEN PED Defines if a key switch opens the gate completely or partially FREE opens partially ca 100 150 cm PLUGGED opens completely Note I...

Страница 14: ...LIM yellow limit switch OPEN should now light up and the gate can be opened as required Otherwise change the limit switch position before further settings are made 5 Close the gate with the button P1...

Страница 15: ...hen slows down 1 The drive is at the limit switch CLOSED LED CLOSE LIM glows 2 Press the button P1 until the gate starts to open LED LEARN glows The automatic programme starts slow speed 3 The drive m...

Страница 16: ...collecting points Batteries and rechargeable batteries are marked with a crossed waste container as well as with the chemical symbol which describes their toxic element Cd for cadmium Hg for mercury a...

Страница 17: ...041ASLG 0185SA Base Housing 041ASLG 1150SA Limit Reader 041ASLG 0383SA Gear Assembly 041ASLG 1004SA Replacement Housing 041ASLG 0198 Worm Gear 041ASLG 0310SA Motor Assembly 041ASLG 0375SA 041ASLG 0353...

Страница 18: ...vy or rough running B Gate blocked or rough running at a certain position C Gate not balanced D Faulty mechanical installation All Consult gate dealer specialist 6x blinking Photocells 1 block install...

Страница 19: ...e gate can move in an uncontrolled dangerous manner if the gate opener has been released A stronger force is needed in the upwards direction of the slope and then in the opposite direction the gate op...

Страница 20: ...aw In Australia in addition to your rights under this Chamberlain Limited Warranty our goods come with guarantees that cannot be excluded under the Australian Consumer Law You are entitled to a replac...

Отзывы: