15
1. The gate is at the limit switch CLOSED.
2. Press P1 and P2 simultaneously for a longer time (about
5-6 seconds) until the gate opens.
Release buttons! LED “LEARN” flashes.
3. Press P1. Soft-stop in the OPENING direction starts from
this position.
4. Press P1 again when the gate moves in CLOSING
direction, soft-stop starts from this position.
When LED "LEARN" goes out, the programming is
completed successfully.
2.
2.
2.
2.
2.
2.
2.
2.
2.
2.
2.
2.
2.
2.
2.
PROGRAMMIING THE TRAVEL DISTANCE AND OPERATOR FORCE
Below are two methods of configuring the opener’s travel
1. Basic Default Setup - Slowest travel
2. Installer setup - Faster travel (optional soft start/soft stop)
1. BASIC DEFAULT FORCE SETTING
(Default speed - fast start then slows down)
1. The drive is at the limit switch CLOSED.
LED "CLOSE LIM" glows.
2. Press the button P1 until the gate starts to open.
(LED "LEARN" glows)
The automatic programme starts (slow speed).
3. The drive moves the gate to the limit switch OPEN,
stops briefly and then moves back to the limit switch CLOSED.
4. After reaching the limit switch CLOSED, the LED
"LEARN" goes out. The programming of the distance and
the force required is completed.
Proceed with “Radio and Radio Programming” and “Completion of Installation”.
2.
2.
2.
2.
2.
2.
2.
2.
2.
2.
2. INSTALLER FORCE SETUP
(Faster speed with optional soft stop function)
PROGRAMMING THE DISTANCE "ADVANCED" (INDIVIDUAL)
NOTE:
The button P1 must be pressed firmly several times during this set up. Each press of the button will determine the position at which the soft-
stop (slow rampdown speed) is activated. ie. The installer can set the soft stop function at any point of the travel.