![MERITECH CleanTech 500EZ Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/meritech/cleantech-500ez/cleantech-500ez_installation-and-operation-manual_1774367006.webp)
6
Facility Installation Instructions
(For detailed specifications, see the system specifications of this manual)
Wall-Mount:
1
Remove wall mount template from packaging.
2
Place top of the wall mount bracket facing up on wall at desired height and location
.
Recommended height is 44” from finished floor to top of wall mounting
bracket,
however top of wall mount bracket
must be a minimum of 26” above the wall drain.
Trace the 6-hole locations from the wall mount bracket onto wall.
3
Install the wall mount bracket with fasteners compatible with wall construction at the 6
traced hole locations. Fasteners length and material should be such that fastener is
capable of supporting a 200-pound vertical force each.
4
Hang the 500EZ onto the wall mount brackets
two “Hooks”. Verify the system is level and
securely attached to the wall.
5
Hook up hot/cold supplies and drain lines.
Do not hard pipe to water inlets of the system
–
Use flexible hoses supplied with system.
Plug in power cord. Install three fresh gallons
of soap per label instructions.
6
Turn water on and inspect for leaks. Repair as necessary.
7
Install the 2 ½ gallon container and verify the solutions meter on the display has full bars.
System is now ready for operation.
CAUTION: Do not ground metal chassis during installation or operation.
Consult local and national codes: conformity and compliance to local and national codes is the
responsibility of the installer.