13
Solution Delivery
During each wash cycle, approximately 5
–
7ml of hygiene solution is injected from its container and
delivered to the hands through the jet nozzles located in the walls of the cylinders. The CleanTech®
500EZ ensures the uniform delivery and dispersal of the antimicrobial solution with adequate water
pressure to the system. At least 40-PSI dynamic (during water flow) inlet water pressure is required.
The system will continuously monitor the delivery of the solution and will automatically signal an
improper delivery on the front panel monitor. Visually examine each container and its clear delivery
lines to determine if there is adequate fluid present and that the line is not blocked. Change the
solution containers if they are empty.
The hand wash cycle consists of a wash and potable water rinse. The wash portion of the cycle mixes
cleansing and sanitizing solution with water followed by a potable water rinse. The cycle length is
normally 12 seconds but can be programmed over a wide timing range. All system programming is
done either at the factory or by an authorized Meritech technician.
DO NOT ATTEMPT TO PROGRAM
OR REPROGRAM YOUR SYSTEM
.
When the hand wash solution container is empty, the light bar will flash empty and the display will
display “ULTRAPURE SOL. EMPTY”
.