Overview 

 
 

Achieving the Optimum Wash 

 
The  CleanTech®  500EZ  system  provides  a  no-touch,  completely  automatic  hand  wash  by  sequentially 
delivering handwashing solution and water in a stimulating spray to the hands or gloves from finger tips 
to  wrist.  The  system  uses  the  Ultrapure  hygiene  solution  and  water  to  remove  99.9%  and  greater 
pathogens  from  the  hands  or  gloves.    The  system  can  also  remove  particles,  sodium

’s

  and  other 

contaminants.    The  standard  system  configuration  is  12  seconds  which  consists  of  a  wash  cycle  using 
hand washing solution that clean and sanitize and a potable water rinse cycle.  A helical configuration of 
jet  nozzles  located  within  the  two  rotating  cylinders  is  used  to  spray  the  mixture  of  solutions  and 
pressurized water onto the hands followed by a potable water rinse.   
 
To  minimize  cross-contamination,  an  infrared  photo  optical  sensor  positioned  directly  above  the 
cylinders automatically senses the presence of your hands when they enter the cylinders.  To trigger a 
wash cycle, it will not be necessary to touch any part of the system; simply insert your hands into the 
cylinders.   
 
One complete hand wash cycle will automatically dispense the appropriate volume of hygiene solution 
followed by a potable water rinse.  The minimum time interval between user cycles is approximately 2 
seconds. 
 
The optional air curtain can be installed on the system to automatically turn on at the end of the cycle 
and blow compressed air on to the hands as long as the photoeye is blocked.  This can be used to just 
knock  of  most  of  the  water  drops  in  just  about  3  seconds  or  used  to  completely  dry  the  hands  in 
approximately 35 seconds. 
 
 
 

Содержание CleanTech 500EZ

Страница 1: ...CleanTech 500EZ INSTALLATION AND OPERATION MANUAL March 31 2020...

Страница 2: ...w meritech com E mail cleantechinfo meritech com E mail service meritech com WARNING The performance and effectiveness of CleanTech systems have been extensively tested when using solutions provided b...

Страница 3: ...Indicators 11 Detailed System Reference 12 Water and Temperature Controls Cylinder Rotation Solution Delivery 13 Changing Solution Containers 14 Removing and Empty Container Installing a New Container...

Страница 4: ...ess This manual describes everything you will need to properly site install and maintain your system The CleanTech 500EZ will connect to your standard hot and cold water lines and drain A more detaile...

Страница 5: ...ons and pressurized water onto the hands followed by a potable water rinse To minimize cross contamination an infrared photo optical sensor positioned directly above the cylinders automatically senses...

Страница 6: ...nd material should be such that fastener is capable of supporting a 200 pound vertical force each 4 Hang the 500EZ onto the wall mount brackets two Hooks Verify the system is level and securely attach...

Страница 7: ...7 New Construction Rough In Diagram...

Страница 8: ...sibility for providing plumbing and electrical modifications to your facility However a Meritech representative will be happy to provide the necessary guidance to ensure a correct installation Follow...

Страница 9: ...SH IN THE SHORTEST PERIOD OF TIME 1 To initiate a cycle stand directly in front of the system and place your hands simultaneously into the center of each cylinder 2 The hygiene cycle will automaticall...

Страница 10: ...y of the hygiene event and the wash you will receive the cleansing solution works properly through a broad range of temperatures The period of time for the warm water to return to the station will dep...

Страница 11: ...are empty and needs to be replaced Master Resettable Compliance Monitor when washing and when rinsing The station also has a countdown timer that counts down from 12 0 and when it hits 0 it is safe to...

Страница 12: ...c application assistance contact Meritech at 1 800 932 7707 Consult with local plumbing authorities for proper connections and installation requirements The customer installed hot and cold water contr...

Страница 13: ...t panel monitor Visually examine each container and its clear delivery lines to determine if there is adequate fluid present and that the line is not blocked Change the solution containers if they are...

Страница 14: ...ase of solutions contains two solution tube assemblies each assembly consists of a cap tube barb with tube Follow these steps for all installations 1 Unscrew the protective cap from the new 2 gallon s...

Страница 15: ...15 Solutions Replacement Diagram...

Страница 16: ...e hose fittings from hot and cold water inlets Remove water filter screens rinse clean with tap water and reinstall water filter screens and hot and cold inlet lines Turn facility water shut off valve...

Страница 17: ...17 Maintenance Continued Taring Warning Symbols The following is a description of the symbols used on the CleanTech 500EZ system Tare Button...

Страница 18: ...18 Unpacking Instruction Preparing system for Unpacking Installation Carefully Remove Tape Carefully Remove Tape Carefully Remove Tape Carefully Remove Tape Carefully Remove Tape...

Страница 19: ...pecification of this manual for further assistance 2 Connect the facility drain to the system drain with P trap 3 Connect the facility hot and cold lines to the system hot and cold inlets 4 Connect th...

Страница 20: ...20 Cut Sheet A Solutions Housing B System Drain C Hot Cold Water Inlets D Water Filter Screens E Power Cord F Air Curtain CDA N2 Inlet F E C D B A...

Страница 21: ...21 Wall Mount Template Use Wall Mount Bracket as the template...

Страница 22: ...inimum 4 15 LPM GPM flow o 40 100 PSI 2 8 6 9 Bar 50 PSI 3 6 Bar optimum water pressure Note Consult Meritech if connecting more than 2 system on the same water lines Drain o Standard 1 1 2 40 mm drai...

Страница 23: ...at No 7 607 443 U S Pat No 7 617 830 U S Pat No 7 641 740 U S Pat No 7 659 824 U S Pat No 7 682 464 U S Pat No 7 698 770 U S Pat No 7 754 021 U S Pat No 7 754 022 U S Pat No 7 757 700 U S Pat No 7 758...

Страница 24: ...codes conformity and compliance to local and nation codes is the responsibility of the installer Consult your local plumbing code for specific details for your location and use a certified plumber for...

Страница 25: ...932 7707 Fax 303 790 4859 www meritech com E mail cleantechinto meritech com E mail service meritech com THE CLEANTECH 500EZ HAS BEEN DESIGNED TO OPERATE SPECIFICALLY WITH THE HAND WASH SOLUTIONS PRO...

Страница 26: ...s and remedies relating to the Product WARRANTY DISCLAIMER MERITECH S RESPONSIBILITY FOR DEFECTS IN THE PRODUCT IS LIMITED TO REPAIR OR REPLACEMENT AT MERITECH S ELECTION AS SET FORTH IN THIS LIMITED...

Страница 27: ...and defend Meritech and its members managers officers affiliates agents and employees against any and all losses damages claims lawsuits demands causes of action judgments liabilities and expenses in...

Отзывы: