16
Maintenance
Weekly:
➢
Pour, rub or spray bleach, ammonium chloride, hydrogen peroxide or other hard surface
disinfectant into each cylinder to kill any bacteria that may be in the system or facility drain.
➢
Clean front surfaces and cylinders with a cleaning agent that removes mineral deposits.
Quarterly:
➢
Clean photo optical sensor lenses with water and a clean soft cloth.
➢
Remove the solution bottle. Fill a container with hot water, put the system solution pickup
tube in the hot water. Run 20-30 hand wash cycles to flush hot water through soap lines.
Let
soak for 15 minutes. Remove the pickup tube from the hot water and run 10 handwashes to
empty the water from the line. Reinstall pickup tube into solution container and run 5
handwashes to re-prime the station.
Biannually:
➢
Unplug system and close facility water shut off valves. Remove hose fittings from hot and
cold-water inlets. Remove water filter screens, rinse clean with tap water and reinstall water
filter screens and hot and cold inlet lines. Turn facility water shut off valves on, plug system in
and check for leaks.
As Needed:
➢
Replace cylinders every 30,000
–
50,000 hand wash cycles or when mineral deposits buildup
or water splash out becomes excessive. This should be done by a Meritech technician.
Taring System:
➢
On occasion it may be necessary to re-tare the solutions scale in the system.
a.
To re-tare the solution scale, remove the solutions container from the system and
verify nothing is on the weigh plate.
b.
Press the tare button and system will go into re-taring mode and display will indicate
taring. This takes only 2 seconds to re-tare the station.
c.
Once complete, re-install the solutions container and verify the solutions light bar is
reading correctly. See next page for a picture of these steps.
ADJUSTMENTS:
Adjustments should be made by a Meritech technician. (See page 20 for contact information)