Section 7 - Troubleshooting
90-864195061 NOVEMBER 2006
Page 135
Power Trim Does Not Operate (Motor Does Not Operate)
Possible Cause
Remedy
Blown fuse.
Replace fuse. Fuses may be located near the dash
trim switch, at the trim pump, in the positive (red)
power trim battery lead near the battery switch, or a
combination of these.
Loose or dirty electrical connections or damaged
wiring.
Check all associated electrical connections and wires
(especially battery cables). Clean and tighten faulty
connection. Repair or replace wiring.
Power Trim Does Not Operate (Motor Operates But Sterndrive Unit
Does Not Move)
Possible Cause
Remedy
Trim pump oil level low.
Fill pump with oil.
Drive unit binding in gimbal ring.
Check for obstruction.