Section 5 - Maintenance
Page 110
90-864195061 NOVEMBER 2006
7. Snap the quick‑connect fitting with the water hose into the flush socket on the engine.
a
b
c
18489
a -
Water hose
b -
Quick‑connect fitting (water hose
end)
c -
Flush socket
8. Open the water source of the water hose to a full flow.
9. Allow the water to flush the sterndrive for 30 seconds.
10. Place the remote control in neutral idle speed position and start engine.
!
CAUTION
Overheating from insufficient cooling water will cause engine and drive system damage.
Ensure that there is sufficient water always available at water inlet holes during operation.
11. Operate the engine at idle speed in neutral gear. Do not exceed 1200 RPM.
12. Monitor the engine temperature while operating the engine.
13. Flush the engine for 5 to 10 minutes or until discharge water is clear.
14. Shut off the engine.
15. Allow the water to flush the sterndrive for 10 seconds.
16. Turn off the water source.
Содержание Sterndrive 350 MAG MPI
Страница 26: ...Section 1 Warranty Notes Page 18 90 864195061 NOVEMBER 2006 ...
Страница 48: ...Section 2 Getting to Know Your Power Package Notes Page 40 90 864195061 NOVEMBER 2006 ...
Страница 70: ...Section 4 Specifications Notes Page 62 90 864195061 NOVEMBER 2006 ...
Страница 138: ...Section 6 Storage Notes Page 130 90 864195061 NOVEMBER 2006 ...
Страница 144: ...Section 7 Troubleshooting Notes Page 136 90 864195061 NOVEMBER 2006 ...