MAINTENANCE
Required Annual Maintenance
The following procedures must be performed each year by a Mendota approved service person.
NOTE: Any adjustments to burner, pilot or logs must be done by a qualified Mendota service person.
1.
Clean all lint and dust build-up around the control. Inspect the condition of any wiring under the burner for melting or damage.
Clean flame sensor rod/hook using emery cloth. Vacuum all burner ports and pilot assembly.
2.
Remove logs & coals and clean away any foreign matter (lint, Carbon, etc.) on the burner and logs. Be sure the burner ports
are "open". Clean the pilot and under side of the logs for any Carbon deposits. NOTE: Logs should be visually checked for
Carbon "build-up". If carbon deposits are visible on logs, unit should be turned off and Mendota service person contacted. Be
sure logs are re-installed per instructions.
3.
Check condition of glass door gasket, gasket must seal tightly over firebox, Inspect gasket along top and sides of glass. If
gasket
at corners of glass are bulging outward or if gasket bulb along top edge or sides are discolored to a white color
appearance
through the whole thickness of the gasket bulb, then replace the gasket. White colored gasket bulb indicates
exhaust leak
through the discolored area and requires replacement of the glass gasket.
Periodic Inspections Required
1.
Check to verify that the vent system and vent cap are open and free of
blockage.
2.
Before re-installing glass, have qualified service person check the
operation of the pilot and cycle the burner per LIGHTING INSTRUCTIONS
(see Owner’s Manual). Be sure all items in LIGHTING and
INSTALLATION "check off” lists are completed.
3.
The viewing glass should be cleaned periodically
.
Exterior glass surface
may be cleaned with cleaner as desired. To clean Interior glass surface,
use Kel Kem “polish plus" (part # 65-06-00455) or comparable
product. Do not use oven cleaner or abrasive cleaners to clean glass. Do
not clean when glass is hot.
4.
Periodic visual check of pilot flames is required. Pilot Flame must overlap
Flame Sensor and burner ignition ports at all times. Especially for LPG
applications, always verify visible pilot flame length is at least 1" long.
5.
Periodic visual check of main burner’s rear and front flames is required.
B
urner Flames
G
eneral Heights Reference Diagram
1" MIN.
1" MIN.
1" MIN.
PAGE 43
Содержание FV44i-0616
Страница 32: ...PAGE 28...
Страница 33: ...PAGE 29...
Страница 34: ...PAGE 30...
Страница 35: ...PAGE 31...
Страница 36: ...PAGE 32...
Страница 37: ...PAGE 33...
Страница 38: ...PAGE 34...
Страница 39: ...PLACE SMALL COALS ON TOP OF FLOOR BRICK PANELS AND CLOSE TO GRATE BOTTOM TO SIMULATE A PAGE 35...
Страница 54: ...NOTES PAGE 50...
Страница 56: ...TAPE SHUT JOHNSON GAS APPLIANCE COMPANY 520 E AVENUE N W CEDAR RAPIDS IA 52405 POSTAGE NEEDED PAGE 52...
Страница 58: ...Johnson Gas Appliance Company 520 E Avenue N W Cedar Rapids IA 52405 Website www mendotahearth com...