SPECIFICATIONS
General Specifications
This Mendota insert must be installed in an existing Masonry Wood Burning Fireplace or a Factory Built ZC Wood Burning
Fireplace. This Mendota insert must be installed and serviced by a Mendota approved technician.
MINIMUM FIREPLACE CAVITY SIZE REQUIREMENT: 33-1/8” WIDE X 24” HIGH X
17-3/4
” DEEP
ELECTRICAL REQUIREMENTS: 120 Volts AC, 1.5 Amps (minimum line voltage allowed 110 Volts AC)
REQUIRED GAS SUPPLY PRESSURE: NAT. GAS: 7" W.C. [5.0" W.C. MIN., 11" W.C. MAX.]
L.P. GAS: 11" W.C. [11" W.C. MIN., 13" W.C. MAX.]
LP GAS CONVERSION KIT: This insert comes configured for use with Natural Gas.
To convert the insert for use with LP Gas install: LP GAS CONVERSION KIT HA-58-00302.
High Fire
Low Fire
BTUH .......................... NAT. GAS 40,000
16,300
BTUH .......................... L.P. GAS
40,000
15,300
ORIFICE SIZE………… REAR BURNER: #42 NAT. [#54 LP]
FRONT BURNER: #45 NAT. [#55 LP]
P.4 EFFICIENCY .......... 82%
FLUE VENTING ............ CO-LINEAR - 4” DIAMETER EXHAUST & 3” DIAMETER INLET
APPROVED VENTS
•
Duravent brand Insert Vent Kits with 3” X 4” Liners and Vent Cap
•
Duravent brand 3” X 4” Liners, 3” X 4” to 4” X 6-5/8” Coaxial Chimney Top Adapter and High Wind Cap
•
ICC brand EXELDirect 3” X 4” Liners and Vent Cap
•
BDM brand 3” X 4” Liners and Vent Cap
•
RLH brand 3” X 4” Liners and Homestyle Series Co-Linear Insert Caps models HS-C43 (4X3)
NET WEIGHT ................ 195 lbs.
SAFETY SCREEN: A safety screen that has been certified for use with this insert must be installed on the insert when it
is in use. The safety screen will prevent accidental contact with the glass door face, which could re-
sult in a severe burns.
SAFETY: AGA certified, electronic ignition IPI system activated with thermostatic remote control.
CERTIFIED TO: ANSI Z21.88 / CSA 2.33 – 2014, CGA 2.17
This Mendota Gas Fireplace Insert has been tested and certified by:
Intertek Testing Services
8431 Murphy Drive, Middleton, WI 53562
PAGE 8
Содержание FV44i-0616
Страница 32: ...PAGE 28...
Страница 33: ...PAGE 29...
Страница 34: ...PAGE 30...
Страница 35: ...PAGE 31...
Страница 36: ...PAGE 32...
Страница 37: ...PAGE 33...
Страница 38: ...PAGE 34...
Страница 39: ...PLACE SMALL COALS ON TOP OF FLOOR BRICK PANELS AND CLOSE TO GRATE BOTTOM TO SIMULATE A PAGE 35...
Страница 54: ...NOTES PAGE 50...
Страница 56: ...TAPE SHUT JOHNSON GAS APPLIANCE COMPANY 520 E AVENUE N W CEDAR RAPIDS IA 52405 POSTAGE NEEDED PAGE 52...
Страница 58: ...Johnson Gas Appliance Company 520 E Avenue N W Cedar Rapids IA 52405 Website www mendotahearth com...