7
5
FV42
85-03-01068
How do I clean the viewing glass?
The viewing glass should be cleaned periodically. Exterior glass surface may be cleaned with cleaner as
desired. To clean interior surface of glass, use soap and water.
Caution:
Do not use oven cleaner or ammonia-
based products to clean glass.
Clean the glass only when it has cooled to room temperature.
Additives that are put in gas (both natural and LP) to make it smell can be harmful to glass and can leave a white film deposit on
the glass. This deposit can be removed with cleaners such as KEL KEM “Polish Plus” (part #65-06-00455) or comparable product.
Contact your Mendota dealer for more information.
Is my flame performance correct?
Your fireplace has air shutters, dampers, coals, and embers that can be adjusted depending on your fuel and
venting configuration. These adjustments should be made by a qualified Mendota technician to achieve the
best flame performance. Contact your installer or Mendota dealer if you feel your fireplace is not burning
correctly. Improper setup and adjustment is not covered under warranty.
What should I do if my fireplace is sooting?
Sooting is caused by improper installation or air shutter operation. However, some small areas of soot
deposits on log surfaces are deemed acceptable. If you observe large soot areas (larger than 1”x1”) on log
surfaces or signs of sooting on the door glass (usually a thin black film on the fireplace viewing glass or on the
outside of the home around the vent cap), the unit
must be immediately turned off
and the local Mendota
dealer promptly informed. Mendota dealers will correct "sooting" problems, but Mendota and their dealers
are
not responsible
for damage caused by excessive sooting that has not been immediately brought to their
attention.
Troubleshooting soot:
Issue:
Thin black coating (soot)
forms on viewing
glass.
Possible Causes:
A. Incorrect gas pressure
B. Not enough combustion
air
C. Leaking glass gasket
D. Vent obstruction
Corrective Action:
Have gas supplier check for correct gas inlet pressure (7" WC nat. gas;
11" WC LP gas). Check glass gasket for proper seal. Corners of glass
gaskets cannot be bulging out. If glass gasket along top edge in the
middle is white in color across entire thickness of gasket bulb, replace
glass gasket.
If sooting continues, open air shutter on burner. If sooting continues,
shut off unit and call Mendota service person.
Note:
To clean glass, remove glass and wipe glass with cloth or paper
towel.
How do I change from Celsius to Fahrenheit on my remote?
To change between °C to °F, follow these steps:
1.
Press the ON/OFF button and turn off the fireplace.
2.
Simultaneously,
press both the mode button and the thermostat button
.
3.
Look at the LCD display to verify that your desired indicator (
°
F or
°
C) is being displayed.
If not, repeat Step 2.