15
FV42
85-03-01068
Technical Specifications
High Fire - Adjustable to - Low Fire
NAT GAS 44,000
14,100
BTUH.
BTUH.
LP GAS 44,000
18,600
NOTE: LPG CONVERSION KIT HA-110-00084, MUST BE PURCHASED SEPARATELY TO CONVERT TO
BURN LPG IN THIS FIREPLACE.
MAIN ORIFICE [0-2000ft (610 m)]: REAR BURNER: #38 NG [54” L.P.] – FRONT BURNER: #44 NG [54“ LP]
[2000-4500ft (610-1370 m)]: REAR BURNER: #38 NG [54” L.P.] – FRONT BURNER: #44 NG [54” LP]
OVERALL EFFICIENCY: ........................................... P.4 FIREPLACE EFFICIENCY, NAT GAS: 74.6% LP GAS: 75%
CO-AXIAL DIRECT VENT FLUE: ............................... 5" INNER, 8" OUTER
TOTAL WEIGHT: ..................................................... 300 POUNDS
SAFETY: .................................................................. AGA/CECERTIFIED IPI AUTO ELECTRONIC IGNITION SYSTEM
ACTIVATED WITH THERMOSTATIC REMOTE CONTROL.
FIREPLACE CERTIFICATION AND TESTING AGENCY
INTERTEK TESTING SERVICES, ICBO#AA647-4
Certified under ANSI Z21.88 (2016) “Vented Gas Fireplace Heaters" not for use with solid fuel. Approved for bedroom installations
and mobile homes. UL307B approved for "mobile homes, after first sale of home, not for recreational vehicles."
GLASS SAFETY SCREEN BARRIER
A certified Glass Safety Screen Barrier must be installed on this fireplace during any use.
GAS REQUIREMENTS
............................................ SUPPLY PRESSURE:
GAS INLET: 1/2" N.P.T.
NAT. GAS:
7" W.C.
(5" W.C. MIN., 11" W.C. MAX.)
LP GAS:
11.0" W.C.
(11" W.C. MIN., 13" W.C. MAX.)
ELECTRICAL REQUIREMENTS
................................ 115 volt, LESS THAN 1.5 Amps (for blower operation only)
APPROVED VENT SYSTEMS
...................... DuraVent, Selkirk, AmeriVent, Security, ICC, Olympia
MINIMUM CLEARANCES TO COMBUSTIBLE CONSTRUCTION
UNIT TO FLOOR
0” (0mm)
INNER GUIDE EDGE TO ADJACENT SIDEWALL
16” (40.5cm)
UNIT TO ENCLOSURE SIDEWALL
½” (13mm)
VENT PIPE TOP TO COMBUSTIBLES
3” (76mm)
UNIT TO ENCLOSURE BACK WALL
½” (13 mm)
VENT PIPE SIDES TO COMBUSTIBLES
1” (25 mm)
UNIT TOP TO ENCLOSURE CEILING
½” (13mm)
VENT PIPE BOTTOM TO COMBUSTIBLES
1” (25mm)
UNIT BOTTOM TO ROOM CEILING
72” (182.9cm)
8” MANTEL ABOVE DISCHARGE AIR OPENING
22”
(56cm)
MINIMUM COMBUSTIBLE ROUGH FRAMING DIMENSIONS (allow extra clearance for vent system)
WIDTH = 55” (127cm)
HEIGHT = 41” (104cm)
DEPTH = 20” (51cm)
THIS FIREPLACE INCLUDES A SEALED COMBUSTION SYSTEM, NEOCERAM GLASS, ELECTRONIC IGNITION SYSTEM, DUAL 105 CFM CONVECTION
AIR BLOWERS, AGA CERTIFIED SAFETY SYSTEM, ACCENT LIGHT and THERMOSTATIC REMOTE CONTROL.
f i r e - p a r t s . c o m
Содержание FV42-0518
Страница 14: ...14 FV42 85 03 01068 Listing Label fire parts com...
Страница 83: ...83 FV42 85 03 01068 fire parts com...