38
FV42
85-03-01068
Attaching LP Gas Conversion Label
A printed informational label is included with the LP Gas Conversion Kit (as shown). Attach this label to the
back surface of the wire diagram plate that is located in the convection air cavity below the firebox:
Checking Burner Ignition Characteristics
Once the conversion to LP gas and all the above steps have been completed, light the main burners.
Use remote control to turn on pilot and burners. Main burner should now
light immediately
and flame should
not "lift" off burner. If there is any delay in ignition or if flame is "lifting off" burner, turn off burner and
carefully check for proper installation of logs/coals, vent system and proper pilot flame impingement on
burner. Logs or coals must not block pilot flame or main burner flame. Vent system must be leak proof.