54
FV42
85-03-01068
Vertical Through-The-Roof Venting Using Four 90
°
Elbows
In extreme situations, four 90
°
elbows may be required to reach a proper exit point for the vent system.
Mendota has spent considerable time and effort in the design of this fireplace and its venting system.
Through this effort, Mendota has been able to certify the use of four 90
°
elbows when terminating vertically.
The use of four 90
°
elbows must meet some minimum prerequisites:
➢
Prerequisite 1: The vent system must terminate vertically using a vertical vent cap.
➢
Prerequisite 2: There must be a minimum 4’ of vertical starter section connected directly to the top
of this fireplace.
LOG SET INSTALLATION
Warning: Logs are breakable!
It is important to handle each log package and every log piece/assembly with extra care.
Breakage is the installer’s responsibility and is not covered by the Warranty Policy.
To access the log set:
1. Open the log set box and
gently remove
the foam packages and lay them on the floor.
2. Use a utility knife to cut tape strips that secure foam package tops to foam package bottoms.
3. Lift off foam package top
slowly and carefully.
If you find that the foam package is upside down,
reverse it before attempting to separate the top and bottom foam trays.
To position each log correctly, refer to the specific log set instruction manual provided with the log set.
H2
H1
V1
V2
H3