ing the DCF-Simulation with the "Timeout" value. DCF Simulation is never suspended, if the delay value is zero.
Single Shot Modus
Selecting Singls Shot generates a single pulse of defined length once per day. You can enter the time when the
pulse is generated with the "Time" value. The value "Length" determines the pulse duration. The pulse duration
can vary from 10 msec to 10 sec in steps of 10 msec.
Pulses Per Second, Per Min, Per Hour Modes
These modes generate pulses of defined length once per second, once per minute or once per hour. "Length"
determines the pulse duration (10 msec...10 sec).
Position OK, Time Sync and All Sync
Three different modes are selectable for output of the clocks synchronization state. The Mode ’Position OK’
activates the output when the receiver has sufficient satellites in view to calculate its position. In "Time Sync"
mode the respective output is activated when the clocks internal timebase is synchronized to the GPS timing.
The "All Sync" Mode performs a logical AND operation of the both states previously mentioned, i.e. the output
is activated if the position can be calculated AND the internal timebase is synchronized to the GPS timing
Idle Mode
Selecting "Idle" deactivates the output.
Holdover
If "enabled" is selected the operation of the output remains. Otherwise ("disabled") the operation of the output
will be switched off when synchronization is lost.
44
Date: 20th March 2020
IMS-GNS181 Setup Guide