4.1.1.7 Fixed Offset and Limit
The "Fixed Offsets" and "Limits" can be entered by using the corresponding fields. The "Fixed Offset" specifies a
fixed offset for each reference clock to the reference time. With this value, known and constant deviations of a
reference time source can be compensated. No constant offset can be set for GNSS references - this can only
be done indirectly with the antenna cable compensation time.
Limit:
Here you can configure a limit value. If the reference source exceeds this limit, a notification is triggered. A
configuration in the Web Interface is required on the Notification page "Notification
→
Notofication Event
→
XMR Limit Exceed".
Figure: Configuration dialog for known offsets and limits.