4.1.1.1 MRS Status
Here the states of the reference inputs are shown:
Priority:
Arrangement of the time source according to your prioritization.
Source:
Type of reference source.
Status:
No Connection,
No signal
→
the reference source is not available.
Signal available
→
the reference source is available.
Is master
→
the reference source is used to synchronize the system.
Is locked
→
the system synchronizes itself to the reference source.
Is accurate
→
Basic accuracy of synchronization reached.
Offset:
Time difference of the reference clock to the specified time source.
Statistics:
Span
→
If the difference between the min / max value
of the time source is over a defined statistical
interval.
Step-Compensation
→
Displays a hard time jump of the reference source
(currently only available for PTP).
Auto-Bias
→
Time offset determined for the source versus an
offset-free time source.
Figure: An example of available reference signals in the priority order.