42 / 54
9018116
9.9.3
Replace counter for partial desalination cartridge (optional)
For dishwashers with a partial desalination cartridge and activated end-of-service
indicator, the counter must be reset after changing the partial desalination car-
tridge.
1. Switch to authorisation level 1
Service level (10001)
, see page 40.
2. To reset the counter, select entry 1-5
.
3. Confirm the selection to reset the value.
The setting level can be departed with the
on/off key
.
9.10 Dosing system level
1. Switch to authorisation level 4, Dosing technology level (40000 or 40044), see
chapter “Change authorisation level” on page 40.
The parameters relevant for the dosing technology are displayed and can be
changed.
Code display Meaning
Adjusting range
P104
Rinse aid dosing quantity
0.10 - 1.00 ml/L
P105
Detergent/disinfectant dosing
quantity
0.10 - 20.0 ml/L
P218
Lack of rinse aid
1/0 = Display on/off
P219
Lack of detergent/disinfectant
1/0 = Display on/off
P224
Rinse aid dosing unit activation
method
0 = Do not activate
1 = Activate through calculated running time
2 = Activate as per pressure booster pump
3 = Activate as per wash pump
P225
Detergent/disinfectant dosing pump
activation method
0 = Do not activate
1 = Activate through calculated running time
2 = Activate as per pressure booster pump
3 = Activate as per wash pump
P321
Rinse aid dosing unit output
0.10 - 10 L/h
P322
Wash pump output
0.10 - 20 L/h
P326
Rinse pipe ventilation time
0 - 255 s
P327
Detergent/disinfectant pipe ventila-
tion time
0 - 100 s
Содержание TopClean M