38 / 54
9018116
122
Incorrect password/no
authorisation
• Code incorrectly en-
tered
• Enter code again
123
Factory setting parame-
ter list
• Switch supply voltage
on/off
• No intervention by the operator is necessary
• Message disappears after 5 min.
126
Maintenance necessary
• The set operating hours
(P 122) or batch num-
ber (P 123) has been
reached
• Possible to continue working
• Call a service technician!
420
Lack of rinse aid (with
integrated fill-level de-
tection)
• Canister empty
• Suction lance not cor-
rectly introduced
• Replace empty canister
• Check suction lance
• Where appropriate, ventilate pipes
520
Lack of detergent/disin-
fectant (with integrated
empty-tank detection)
ERR
Description
Possible cause
Measures/remedial action
001
EEPROM error
• EEPROM
– Not present/defective
– Installed incorrectly
– Incorrect data/empty
• Not possible to continue
working
• Call a service technician!
111
Floor pan leakage
• There is a leak
• Not possible to continue
working
• Call a service technician!
117
Door not locked
• The pin of the lifting magnet is not
correctly in the locking device
• The magnetic coil of the lifting
magnet is damaged
• Door locking query is not correct
201
Boiler level not reached during
first filling (with integrated pres-
sure booster pump)
• Fresh water inlet insufficient (wa-
ter tap closed)
• Feed hose kinked/discon-
nected/leaks
• Inlet filter soiled
• Solenoid valve defective
• Boiler switch defective
• Check water supply
• Check feed hose
• Check pre-filter/sieve and
clean, if necessary
• Where appropriate, call a
service technician!
202
Boiler level not reached on time
during filling (with integrated
pressure booster pump)
203
No change detected by the
boiler level switch when empty-
ing (with integrated pressure
booster pump)
• Pressure booster pump defective
• Plug connections disconnected
(e.g. pressure booster pump)
• Start capacitor defective
• Boiler level switch defective
• No signal to or from pressure
booster pump and I/O circuit
board
• No signal boiler full - from I/O cir-
cuit board
• Not possible to continue
working
• Call a service technician!
204
No change yet detected at the
boiler level switch (with inte-
grated pressure booster pump
installed) after the rinse time ex-
pired
205
Boiler temperature not reached
after max. heat time (P310)
• Boiler heating defective/melting
beads, heating element
• Temperature sensor defective, in-
correct installation position
• Boiler protection defective, output
switch triggered
• No signal from I/O circuit board
• Not possible to continue
working
• Call a service technician!
206
Wash time increase
• Boiler not ready for final rinse on
time (temperature or level not
reached)
• Boiler heating defective (melting
beads)
• Acknowledge message, con-
tinued work possible
• Let programme run without
intervention by the operator