20
Asset Test Groups
Appliances are referred to as “Assets”. For each asset a complete record is stored under the appropriate Client. Each asset record holds full details of
the equipment, i.e. ID; Description; Serial number; Fuse rating; Test Group, VA Rating, Test frequency, Room, and Test results.
ASSET ID
(Unique Reference)
ASSET RECORD
(e.g. Drill)
GROUP DETAILS
ASSET DETAILS
TEST RESULTS
(e.g. DRL2
(e.g. Description
FOR ASSET
Drill Class 2
Fuse Rating
+ TEST SETUP
VA Rating
+ TEST LIMITS
Test Frequency
Serial number
Group Room
A Test Group is a set of pre-defined tests with associated pass / fail limits that are suitable for a specified type of asset (appliance). Up to 50 Test Groups
may be configured, each of which is identified by a User designated 3-character code. Every asset record contains a Group
PAT4
should use when
the appliance is tested.
Each Group contains the following information: -
Group Code:
e.g. DRL
Group name:
e.g. Drills
Voltage:
230V or 110V
Insulation Class:
Class 1 = Earthed
Class 2 = Double insulated.
Tests to be applied: e.g.
Bond test
Insulation test
Operation test etc.
When setting up a Group, any of the
PAT4
tests may be specified by placing a
3
next to the selected tests.
Note:
The Earth leakage/touch current test is part of the Operation test – enable the Operation test to include an Earth leakage/touch current test.