Zero offset at probe tips:
0,10
Ω
typical
Lead resistance zeroing:
Up to 9,99
Ω
Noise rejection:
1V rms 50/60Hz
Buzzer:
Operates at less than 5
Ω
(approx).
Resistance
Measuring Range:
0,01k
Ω
to 9,99M
Ω
(0 to 100M
Ω
on analogue scale)
Accuracy: ±3%
± 2digits
Open circuit voltage:
5V ±1V
Short circuit current:
25µA ±5µA
Voltage
Measuring Range:
±1V to ±500V
(0 to 1000V on analogue scale)
Accuracy:
0-500V d.c. ±2% ±3 digit
0-500V a.c (50/60Hz) ±2% ±3 digits
0-500V 400Hz a.c. ±5% ±3 digits
Input resistance:
approx 200k
Ω
.
Detector Threshold:
1V
Millivolts
Measuring Range:
±0,1mV to ±1999mV
(0 to 1000mV on analogue scale)
Accuracy: 0,1mV to 10mV d.c. or a.c. (50/60Hz) ±2% ±5 digits
10mV to 1999mV d.c. or a.c. (50/60Hz) ±2% ±3 digits
0,1mV to 10mV a.c. (16-460 Hz) ±5% ±7 digits
10mV to 1999mV a.c. (16-460 Hz) ±5% ±5 digits
d.c. milliVolts zeroing:
Up to 9,9mV
Input resistance:
>3M
Ω
Capacitance
(BMM2080)
Measuring Range:
0,1nF to 9,99uF
Accuracy:
±3% ±2 digits ±0,2nF
uF zeroing:
Up to 10nF
Milli-amps
(Not BMM 2000ESD)
Measuring Range:
0,1mA to 500mA
(0 to 1000mA on analogue scale)
Accuracy: 0,1mA to 10mA d.c. or a.c. (50/60Hz) ±2% ±5 digits
10mA to 500mA d.c. or a.c. (50/60Hz) ±2% ±3 digits
0,1mA to 10mA a.c.(16-460Hz) ±5% ±7 digits
10mA to 500mA a.c. (16-460Hz) ±5% ±5 digits
Frequency
Measuring range:
16Hz to 460Hz
Accuracy:
±1% ±1digit
Basic and service errors for Insulation and Resistance ranges
The basic error is the maximum inaccuracy of the instrument
under ideal conditions, whereas the service error is the
maximum inaccuracy taking into effect of battery voltage,
temperature, interference, and system voltage and frequency,
where applicable. After determining the service error, we can