M
AVTM246004 BITE 2/2P Rev 4 July 2011
82
Replacing Fuses in
the BITE 2
Transmitter
If you identify a fuse problem and suitably trained repair
personnel are available to perform the operation, refer to the
following subsections to replace primary and secondary
fuses.
Replacing the BITE 2
Transmitter Primary
Fuse
To replace the BITE 2 transmitter primary fuse:
1.
Remove the
transmitter
from the vicinity of the battery
room.
2.
Press the
transmitter
power switch to the
O
(OFF)
position. Then disconnect the ac power cord from the ac
outlet.
3.
Remove the
current source leads
from the battery under
test.
F
WARNING
Do not remove the BITE 2 transmitter current source
leads from the battery until the BITE 2 transmitter is
powered down. Always disconnect the current source
leads from the battery before removing them from the J2
connector on the transmitter.
4.
Remove the
current source leads
from the J2 connector
on the
transmitter
.
5.
Remove the fuse carrier from the power module on the
transmitter
.
If the fuse is not bad, refer to
"Identifying a Secondary Fuse
Problem" on page 81.
6.
Remove the damaged fuse and replace with exact
replacement spares (not provided) as specified in
Appendix
B: Replaceable Parts List
. Verify with an ohmmeter that
the removed fuse is indeed bad.
www.
GlobalTestSupply
.com
Find Quality Products Online at: