PAT100 SERIES

Handheld portable appliance testers

UK

Archcliffe Road Dover

CT17 9EN England

T +44 (0) 1304 502101

F +44 (0) 1304 207342

[email protected]

UNITED STATES

4271 Bronze Way

Dallas TX 75237-1019 USA

T 800 723 2861 (USA only)

T +1 214 333 3201

F +1 214 331 7399

[email protected]

OTHER TECHNICAL SALES OFFICES

Valley Forge USA, College Station USA,  

Sydney AUSTRALIA, Danderyd SWEDEN,  

Ontario CANADA, Trappes FRANCE,  

Oberursel GERMANY, Aargau SWITZERLAND, 

Kingdom of BAHRAIN, Mumbai INDIA, 

Johannesburg SOUTH AFRICA, Chonburi THAILAND

CERTIFICATION ISO

Registered to ISO 9001:2008 Cert. no. Q 09290

Registered to ISO 14001-2004 Cert. no. EMS 61597

PAT100_SB_en_V01

www.megger.com

Megger is a registered trademark

ORDERING INFORMATION

Description 

Order Code

PAT120-UK PORTABLE APPLIANCE TESTER 

1003-062

PAT150-UK PORTABLE APPLIANCE TESTER 

1003-064

PAT150R-UK PORTABLE APPLIANCE TESTER 

1003-428

Included accessories for PAT120

Extension lead adaptor BS1363 

1001-234

Continuity/earth bond lead 

1001-233

Carry case 

1005-075

Included accessories for PAT150

Continuity/earth bond lead 

1001-233

SELV/mains voltage test lead Red x1 

1005-077

Extension lead adaptor BS1363 

1001-234

Mains plug test lead 

6231-601

Carry case 

1005-075

Included accessories for PAT150R

AC Mains charger – multi-country 

1003-436

Optional accessories

Plug adaptor IEC C6 - C13 

2000-551

Roll of 1000 PASS test labels 

1000-971

PAT test certificate book 

1001-299

PTDVD - DVD covering Portable Appliance Testing  1002-384

EMC

Design to meet IEC 61326-1: 2006 and IEC 61326-2-2: 

2005.

Fuse

(user replaceable)
UK variants has mains plug fuse
One F 100 mA 250 V 5 x 20 mm HBC fuse.

ENVIRONMENTAL

Operating temperature 

range

0°C to +40°C  

Storage temperature range

-20°C to +60°C

Humidity

90%RH @ +10°C +30°C
75%RH @ +30°C to +40°C

Maximum altitude

2,000m to full safety spec.

IP rating

IP40 (with front cover closed)

MECHANICAL

BATTERIES

Battery life

3 days based on 120 tests/
day using 2000 mAh Alkaline 
batteries

Battery type

Supply voltage
12 Vdc (Alkaline AA LR6)
9.6 Vdc (NiMH AA LR6) 

WEIGHT

PAT120 (instrument only): 1150 g
Shipping weight: 2370g 

PAT150 (instrument only): 1300 g
Shipping weight: 2795g

PAT150R (instrument only): 1300 g
Shipping weight: 2975

DIMENSIONS

Dimensions (instrument 

and case)

203mm (L) x 148mm (W) x 78mm 
(H) 

Dimensions (instrument 

and packaging)

456mm(L) x 178mm (W) x 89mm 
(H)

Содержание 1003-062

Страница 1: ...PAT120 Series Portable Appliance Tester User Guide WWW MEGGER COM...

Страница 2: ...ION symbols 8 Carry strap fitting and removal 9 Switching ON OFF 10 Class I test PAT120 using substitute leakage 40 V ac 11 Class II test PAT120 Using Substitute Leakage 40 V ac 12 Power cord test PAT...

Страница 3: ...ured by Megger Instruments Limited Archcliffe Road Dover Kent CT17 9EN England Megger Instruments Limited reserves the right to change the specification of these instruments at any time without prior...

Страница 4: ...the Appliance tester During testing ensure no hazard will exist as a result of normal running or under fault conditions During testing the unit under test appliance should not be touched other than u...

Страница 5: ...tion Earth pin of the 230 V test socket will become hazardous if test lead P1 is in contact with hazardous voltages during continuity test Product Safety Category CATII 300 V MEASUREMENT CATEGORY II E...

Страница 6: ...PASS FAIL Neck strap slot Test groups Power ON Hold for 0 5s Backlight Main test socket Symbols used on the connection panel PAT120 connector panel G Do NOT connect P1 and P3 sockets to hazardous liv...

Страница 7: ...ive method 40 V ac leakage test for for touch current Battery powered test Cable polarity correct Power lead or Extension lead polarity test Live to Neutral cross polarity Test probe P1 to be connecte...

Страница 8: ...pment to be tested to the instrument Connect the P1 test lead to socket P1 on the Pat100 and the probe to exposed metalwork Ensure the probe is NOT connected to a 230V source Connect the P1 test lead...

Страница 9: ...www megger com 9 Carry strap fitting and removal Fitting the carry strap Removing carry strap...

Страница 10: ...Switching ON i ii iii PAT120 iv 0 5 s Switching OFF i Manual OFF ii Auto OFF 2 s Unit switches after 3 minutes of inactivity not adjustable Backlight Aborting a test A test can be aborted at any time...

Страница 11: ...be P1 is connected vi Remove probe P1 See note below vii viii Class I Pass NOTE If the contact symbol is displayed during the test the PAT has detected an open circuit load Ensure the appliance is swi...

Страница 12: ...on test 500 V OR Insulation test 250 V 2 s iv Ensure probe P1 is connected v Repeat contact on all exposed conductive parts vi See note below vii Class II Pass NOTE If the contact symbol appears the a...

Страница 13: ...www megger com 13 Power cord test PAT120 Testing a standard power cord i ii iii iv Insulation test 500 V OR Insulation test 250 V 2 s v vi...

Страница 14: ...www megger com 14 Extension lead test PAT120 Testing an extension lead or multi way extension lead i ii iii Insulation test 500 V OR Insulation test 250 V 2 s iv v vi vii...

Страница 15: ...idual test fail indicated by a small cross ii Overall FAIL indicated by a large cross Note Once an appliance has failed a test further testing of the test group sequence is prevented for safety reason...

Страница 16: ...5xI N10 ms PAT120 UK 0 2 0 2 0 2 1 2 1 3 5 0 25 NA NA NA NA PAT120 DE PAT120 CH PAT120 EU 0 3 0 3 0 3 1 2 1 3 5 0 5 NA NA NA NA International model variations Continuity retest after fail PAT120 DE CH...

Страница 17: ...e instrument They can be safely removed by ensuring all test leads have been disconnected from the instrument prior to removing the battery cover with a suitable screwdriver Spent PAT100 batteries are...

Страница 18: ...ltage 4V dc 0 10 open circuit Test current Bi directional 200mA 0 50mA into 2 load Continuity accuracy resistance 5 3 digits 0 to 19 99 Resistance resolution 10 m Display range 0 01 to 19 99 Test time...

Страница 19: ...2012 and IEC 61326 2 2 2005 FUSE user replaceable UK variants has mains plug fuse One F 100 mA 250 V 5 x 20 mm HBC fuse ENVIRONMENTAL Operating temperature range 0 C to 40 C Storage temperature range...

Страница 20: ...01 E ausales megger com Megger 4271 Bronze Way Dallas TX 75237 1017 U S A Tel 1 800 723 2861 U S A only Tel 1 214 330 3203 International Fax 1 214 337 3038 Megger Valley Forge Corporate Centre 2621 Va...

Страница 21: ...ontinuity insulation mains powered leakage testing and SELV measurements can be made using the Quick Test QT button Test group pass limits and test duration can be configured by the user Bond lead res...

Страница 22: ...ld be tested to ensure the output voltage does not exceed maximum limits as defined in the international regulations for Extra Low voltage systems The PAT150 permits up to 50 V ac measurement with a P...

Страница 23: ...Nominal mains frequency 50 Hz Test accuracy 5 3d 3uA A Resolution 0 01 mA Display range 0 10 to 19 99 mA Test duration User selectable from 2 sec to 5 seconds TOUCH CURRENT TEST Test voltage Nominal m...

Страница 24: ...arth bond lead 1001 233 SELV mains voltage test lead Red x1 1005 077 Extension lead adaptor BS1363 1001 234 Mains plug test lead 6231 601 Carry case 1005 075 Included accessories for PAT150R AC Mains...

Отзывы: