background image

www.megger.com

17

Battery and Fuse replacement (PAT120)

Battery type: 8 x 1.5 V Alkaline LR6 (AA) or NiMH HR6 rechargeable
Battery condition is shown by the following display symbols:

100%

Full

75%

50%

25%

<25%

Exhausted (Flashing)

For battery replacement:

 

a) Remove old cells and refit new batteries following correct polarity as marked on  

 

the battery holder. 

 

Either:   8 x 1.5 V AA / LR6 Alkaline

 

 

8 x 1.2 V AA / LR6 NiMH

 

c) Replace the battery cover.

Warning:

 Incorrect battery cell polarity can cause electrolyte leakage, resulting in damage to 

the instrument.

Warning:

 Do not mix battery technologies 

Warning:

 Do not use batteries with different charge state

Battery Disposal

The crossed out wheeled bin symbol placed on the batteries is a reminder not to dispose of 
them with general waste at the end of their life.

This product contains the following batteries: 
 

8 x AA Alkaline (LR6) 1.5V primary cells

They are located in the battery compartment on the rear of the instrument
They can be safely removed by ensuring all test leads have been disconnected from the 
instrument prior to removing the battery cover with a suitable screwdriver.
 
Spent PAT100 batteries are classified as Portable Batteries and should be disposed of in the 
UK in accordance with Local Authority requirements
 
For disposal of batteries in other parts of the EU contact your local Megger company or 
distributor.

Megger is registered in the UK as a producer of batteries.
The Registration number is BPRN00142

For Further information see www.megger.com

To replace batteries or fuse:  
 

Switch off the instrument. 

 

Disconnect the instrument from all electrical circuits. 

Battery

 

replacement

  

 

 

Remove the battery cover from the base by using a cross head screwdriver to un 

 

screw the battery cover fixing screw.

  

Spent Alkaline and NiMH batteries are 
classified as portable batteries and should 
be disposed of in the UK in accordance with 
Local Authority requirements. For disposal of 
batteries in other parts of the EU contact your 
local distributor.

Megger is registered in the UK as a producer of 
batteries.
The Registration number is BPRN 00142

Содержание 1003-062

Страница 1: ...PAT120 Series Portable Appliance Tester User Guide WWW MEGGER COM...

Страница 2: ...ION symbols 8 Carry strap fitting and removal 9 Switching ON OFF 10 Class I test PAT120 using substitute leakage 40 V ac 11 Class II test PAT120 Using Substitute Leakage 40 V ac 12 Power cord test PAT...

Страница 3: ...ured by Megger Instruments Limited Archcliffe Road Dover Kent CT17 9EN England Megger Instruments Limited reserves the right to change the specification of these instruments at any time without prior...

Страница 4: ...the Appliance tester During testing ensure no hazard will exist as a result of normal running or under fault conditions During testing the unit under test appliance should not be touched other than u...

Страница 5: ...tion Earth pin of the 230 V test socket will become hazardous if test lead P1 is in contact with hazardous voltages during continuity test Product Safety Category CATII 300 V MEASUREMENT CATEGORY II E...

Страница 6: ...PASS FAIL Neck strap slot Test groups Power ON Hold for 0 5s Backlight Main test socket Symbols used on the connection panel PAT120 connector panel G Do NOT connect P1 and P3 sockets to hazardous liv...

Страница 7: ...ive method 40 V ac leakage test for for touch current Battery powered test Cable polarity correct Power lead or Extension lead polarity test Live to Neutral cross polarity Test probe P1 to be connecte...

Страница 8: ...pment to be tested to the instrument Connect the P1 test lead to socket P1 on the Pat100 and the probe to exposed metalwork Ensure the probe is NOT connected to a 230V source Connect the P1 test lead...

Страница 9: ...www megger com 9 Carry strap fitting and removal Fitting the carry strap Removing carry strap...

Страница 10: ...Switching ON i ii iii PAT120 iv 0 5 s Switching OFF i Manual OFF ii Auto OFF 2 s Unit switches after 3 minutes of inactivity not adjustable Backlight Aborting a test A test can be aborted at any time...

Страница 11: ...be P1 is connected vi Remove probe P1 See note below vii viii Class I Pass NOTE If the contact symbol is displayed during the test the PAT has detected an open circuit load Ensure the appliance is swi...

Страница 12: ...on test 500 V OR Insulation test 250 V 2 s iv Ensure probe P1 is connected v Repeat contact on all exposed conductive parts vi See note below vii Class II Pass NOTE If the contact symbol appears the a...

Страница 13: ...www megger com 13 Power cord test PAT120 Testing a standard power cord i ii iii iv Insulation test 500 V OR Insulation test 250 V 2 s v vi...

Страница 14: ...www megger com 14 Extension lead test PAT120 Testing an extension lead or multi way extension lead i ii iii Insulation test 500 V OR Insulation test 250 V 2 s iv v vi vii...

Страница 15: ...idual test fail indicated by a small cross ii Overall FAIL indicated by a large cross Note Once an appliance has failed a test further testing of the test group sequence is prevented for safety reason...

Страница 16: ...5xI N10 ms PAT120 UK 0 2 0 2 0 2 1 2 1 3 5 0 25 NA NA NA NA PAT120 DE PAT120 CH PAT120 EU 0 3 0 3 0 3 1 2 1 3 5 0 5 NA NA NA NA International model variations Continuity retest after fail PAT120 DE CH...

Страница 17: ...e instrument They can be safely removed by ensuring all test leads have been disconnected from the instrument prior to removing the battery cover with a suitable screwdriver Spent PAT100 batteries are...

Страница 18: ...ltage 4V dc 0 10 open circuit Test current Bi directional 200mA 0 50mA into 2 load Continuity accuracy resistance 5 3 digits 0 to 19 99 Resistance resolution 10 m Display range 0 01 to 19 99 Test time...

Страница 19: ...2012 and IEC 61326 2 2 2005 FUSE user replaceable UK variants has mains plug fuse One F 100 mA 250 V 5 x 20 mm HBC fuse ENVIRONMENTAL Operating temperature range 0 C to 40 C Storage temperature range...

Страница 20: ...01 E ausales megger com Megger 4271 Bronze Way Dallas TX 75237 1017 U S A Tel 1 800 723 2861 U S A only Tel 1 214 330 3203 International Fax 1 214 337 3038 Megger Valley Forge Corporate Centre 2621 Va...

Страница 21: ...ontinuity insulation mains powered leakage testing and SELV measurements can be made using the Quick Test QT button Test group pass limits and test duration can be configured by the user Bond lead res...

Страница 22: ...ld be tested to ensure the output voltage does not exceed maximum limits as defined in the international regulations for Extra Low voltage systems The PAT150 permits up to 50 V ac measurement with a P...

Страница 23: ...Nominal mains frequency 50 Hz Test accuracy 5 3d 3uA A Resolution 0 01 mA Display range 0 10 to 19 99 mA Test duration User selectable from 2 sec to 5 seconds TOUCH CURRENT TEST Test voltage Nominal m...

Страница 24: ...arth bond lead 1001 233 SELV mains voltage test lead Red x1 1005 077 Extension lead adaptor BS1363 1001 234 Mains plug test lead 6231 601 Carry case 1005 075 Included accessories for PAT150R AC Mains...

Отзывы: