The PAT100 series of hand-held portable appliance testers enable 
simple, fast safety testing in all environments including offices, 
shops and business units. It is ideally suited to training organisations 
with a very short learning curve and tough, reliable functionality.
With rubber armoured cases and fitted with hardened, scratch proof 
glass, the PAT100s are exceptionally tough instruments.

Battery powered operation makes the PAT100s perfect for those 
locations where an electrical supply is not available, inconvenient or 
unsafe, especially building sites and warehouses. The PAT100 series 
conforms to all UK and European requirements for electrical safety 
testing.

Test groups

Test groups enable the correct sequence of tests to be performed 
automatically with minimum intervention by the user. This keeps 
testing simple, reduces test times to a minimum and helps to 
prevent testing errors.

PAT120:

  

The PAT120 model has test groups available for Class I, Class II 
and Extension/Power leads. 

Fixed PASS limits.

Insulation testing at 500 V (default) or 250 V can be selected at 
the start of the test.

Leakage testing uses a “Substitute Leakage” also known as the 
“Alternative” method to remove the need for a mains supply 
during test.

The PAT150:

 

The PAT150 has additional tests available for testing portable 
RCDs (PRCDs) of 10 mA and 30 mA. 

Separate tests for continuity, insulation, mains powered leakage 
testing and SELV measurements can be made using the Quick 
Test (QT) button.

Test group pass limits and test duration can be configured by the 
user.

Bond lead resistance can be nulled to reduce measurement 
errors.

Live circuit measurement is available for testing the mains supply 
and socket polarity or electrical circuit voltage to 300 V ac. 

Can be used for testing fixed appliances.

Continuity test

Used for measuring the proper bonding of all metal parts of a class I 
device to the protective conductor.
Tests are performed at 200 mA dc in both polarities to be compliant 
with international and UK regulation or recommendations. This test 
is safe to perform on equipment where higher test currents could 
cause damage.

Insulation testing

Used for measuring the separation of conductive parts or 
conductors from earth. This test is usually performed at 500 V dc. 
The PAT100 series maintain the necessary test voltage down to 0.5 
Mohms.

 www.megger.com

PAT100 SERIES

Handheld portable appliance testers

PAT100 SERIES

Handheld portable appliance testers

Simple tick or cross, pass or fail indication plus 
measurement

Battery powered with rechargeable options

Includes 250 V insulation and leakage testing 
for safe IT testing and surge protected devices

Testing portable and fixed electrical equipment

10 mA and 30 mA portable RCD lead testing 
(PAT150)

Adjustable PASS test limits (PAT150)

Substitute and mains powered leakage testing 
(PAT150)

Tough, rubber armoured with built-in front 
cover, hardened, scratch proof display window

Содержание 1003-062

Страница 1: ...PAT120 Series Portable Appliance Tester User Guide WWW MEGGER COM...

Страница 2: ...ION symbols 8 Carry strap fitting and removal 9 Switching ON OFF 10 Class I test PAT120 using substitute leakage 40 V ac 11 Class II test PAT120 Using Substitute Leakage 40 V ac 12 Power cord test PAT...

Страница 3: ...ured by Megger Instruments Limited Archcliffe Road Dover Kent CT17 9EN England Megger Instruments Limited reserves the right to change the specification of these instruments at any time without prior...

Страница 4: ...the Appliance tester During testing ensure no hazard will exist as a result of normal running or under fault conditions During testing the unit under test appliance should not be touched other than u...

Страница 5: ...tion Earth pin of the 230 V test socket will become hazardous if test lead P1 is in contact with hazardous voltages during continuity test Product Safety Category CATII 300 V MEASUREMENT CATEGORY II E...

Страница 6: ...PASS FAIL Neck strap slot Test groups Power ON Hold for 0 5s Backlight Main test socket Symbols used on the connection panel PAT120 connector panel G Do NOT connect P1 and P3 sockets to hazardous liv...

Страница 7: ...ive method 40 V ac leakage test for for touch current Battery powered test Cable polarity correct Power lead or Extension lead polarity test Live to Neutral cross polarity Test probe P1 to be connecte...

Страница 8: ...pment to be tested to the instrument Connect the P1 test lead to socket P1 on the Pat100 and the probe to exposed metalwork Ensure the probe is NOT connected to a 230V source Connect the P1 test lead...

Страница 9: ...www megger com 9 Carry strap fitting and removal Fitting the carry strap Removing carry strap...

Страница 10: ...Switching ON i ii iii PAT120 iv 0 5 s Switching OFF i Manual OFF ii Auto OFF 2 s Unit switches after 3 minutes of inactivity not adjustable Backlight Aborting a test A test can be aborted at any time...

Страница 11: ...be P1 is connected vi Remove probe P1 See note below vii viii Class I Pass NOTE If the contact symbol is displayed during the test the PAT has detected an open circuit load Ensure the appliance is swi...

Страница 12: ...on test 500 V OR Insulation test 250 V 2 s iv Ensure probe P1 is connected v Repeat contact on all exposed conductive parts vi See note below vii Class II Pass NOTE If the contact symbol appears the a...

Страница 13: ...www megger com 13 Power cord test PAT120 Testing a standard power cord i ii iii iv Insulation test 500 V OR Insulation test 250 V 2 s v vi...

Страница 14: ...www megger com 14 Extension lead test PAT120 Testing an extension lead or multi way extension lead i ii iii Insulation test 500 V OR Insulation test 250 V 2 s iv v vi vii...

Страница 15: ...idual test fail indicated by a small cross ii Overall FAIL indicated by a large cross Note Once an appliance has failed a test further testing of the test group sequence is prevented for safety reason...

Страница 16: ...5xI N10 ms PAT120 UK 0 2 0 2 0 2 1 2 1 3 5 0 25 NA NA NA NA PAT120 DE PAT120 CH PAT120 EU 0 3 0 3 0 3 1 2 1 3 5 0 5 NA NA NA NA International model variations Continuity retest after fail PAT120 DE CH...

Страница 17: ...e instrument They can be safely removed by ensuring all test leads have been disconnected from the instrument prior to removing the battery cover with a suitable screwdriver Spent PAT100 batteries are...

Страница 18: ...ltage 4V dc 0 10 open circuit Test current Bi directional 200mA 0 50mA into 2 load Continuity accuracy resistance 5 3 digits 0 to 19 99 Resistance resolution 10 m Display range 0 01 to 19 99 Test time...

Страница 19: ...2012 and IEC 61326 2 2 2005 FUSE user replaceable UK variants has mains plug fuse One F 100 mA 250 V 5 x 20 mm HBC fuse ENVIRONMENTAL Operating temperature range 0 C to 40 C Storage temperature range...

Страница 20: ...01 E ausales megger com Megger 4271 Bronze Way Dallas TX 75237 1017 U S A Tel 1 800 723 2861 U S A only Tel 1 214 330 3203 International Fax 1 214 337 3038 Megger Valley Forge Corporate Centre 2621 Va...

Страница 21: ...ontinuity insulation mains powered leakage testing and SELV measurements can be made using the Quick Test QT button Test group pass limits and test duration can be configured by the user Bond lead res...

Страница 22: ...ld be tested to ensure the output voltage does not exceed maximum limits as defined in the international regulations for Extra Low voltage systems The PAT150 permits up to 50 V ac measurement with a P...

Страница 23: ...Nominal mains frequency 50 Hz Test accuracy 5 3d 3uA A Resolution 0 01 mA Display range 0 10 to 19 99 mA Test duration User selectable from 2 sec to 5 seconds TOUCH CURRENT TEST Test voltage Nominal m...

Страница 24: ...arth bond lead 1001 233 SELV mains voltage test lead Red x1 1005 077 Extension lead adaptor BS1363 1001 234 Mains plug test lead 6231 601 Carry case 1005 075 Included accessories for PAT150R AC Mains...

Отзывы: