SPECIFICATIONS
ENVIRONMENTAL CONDITION:
Operating ambient
Humidity
20°C
Nominal humidity
CONTINUITY TEST
Test voltage
Compliance Voltage: +4V dc
–0 % /+10 % (open circuit)
Test current
Bi-direc200mA
-0% + 50mA (into 2Ω load)
Continuity accuracy
Resistance: ± 5% ± 3 digits (0 to
19.99 Ω)
Resistance resolution
10 mΩ
Display range
0.01 to 19.99Ω
Continuity test nulling
up to 9.99 Ω
Test time
User selectable from 2 sec to 20
sec or selected during test to
180sec
INSULATION TEST
Insulation test
250V dc –0 % /+25 % open
circuit
500V dc –0 % /+25 % open
circuit
≥ 500V 0% dc across 0.5 MΩ
load
Short circuit/charge current
< 2mA dc
Insulation accuracy
±3% ±10 digits (0 to 19.99 MΩ)
Resolution
0.01 MΩ
Display range
0.10 MΩ to 99.99 MΩ
Test duration
User selectable from 2 sec to 20
sec or selected during test to
180sec
SUBSTITUTE LEAKAGE TEST
Leakage current
Accuracy ± 5% ± 3 digits
Test frequency
Nominal mains frequency 50Hz
Test voltage
< 50V ac
Resolution
0.01mA
Display range
0.10 to 19.99mA
Test duration
User selectable from 2 sec to 5
seconds
Reading corrected to 230V ac.
DIFFERENTIAL LEAKAGE CURRENT
Test voltage
Nominal supply voltage 230 V ac
Test frequency
Nominal mains frequency 50 Hz
Test accuracy
±5% ±3d ±3uA/A
Resolution
0.01 mA
Display range
0.10 to 19.99 mA
Test duration
User selectable from 2 sec to 5
seconds
TOUCH CURRENT TEST
Test voltage
Nominal mains 230 V ac
Test frequency
Nominal mains 50 Hz
Test accuracy
± 5% ± 3 digits
Resolution
0.01 mA
Display range
0.10 to 3.99 mA
Test duration
User selectable from 2 sec to 5
sec
SELV DEVICE TEST
Test voltage
0 to 300 V ac
Measurement accuracy
± 3% ± 3 digits
Resolution
0.1 V ac
Display range
0.1 to 300 V ac
EXTENSION LEAD TEST
Test includes Insulation and Bond tests.
Test voltage
5V
Polarity
Lead OK
Live/neutral shorted
Live/neutral reversed
Live/neutral open circuit
PORTABLE RCD TEST
Test voltage
Nominal mains 230 V
Test frequency
50Hz
Test current accuracy
+2% to +8% (1 x I, 5 x I)
Trip time accuracy
±1% ± 1ms
Trip time resolution
0.01ms
Display range
0 to 200ms (1 x I)
0 to 40ms (5 x I)
MAINS SUPPLY TEST
Frequency measurement
range
50 Hz
Test voltage
40 to 300V ac
Accuracy
± 3% ± 3 digits
Resolution
0.1Vac
Display range
40 to 300V ac
CIRCUIT TEST
(Carried out automatically, not available to user)
Test voltage
5V
Test frequency
Nominal Mains 50 Hz
Test current
< 100mA short circuit
Safety
Instrument designed to IEC 61010-1: 2012
Test leads designed to IEC 61010-031: 2005
300 volts to Earth Category II
Mains fuse protection to 250 volts rms ac