PAT100 SERIES

Handheld portable appliance testers

An additional 250 V dc insulation test is available on all models 
for use on IT equipment, on devices or extension leads that are 
fitted with surge protection, or simply where it may be considered 
undesirable to use a 500 V test. 

Substitute leakage testing

Substitute leakage testing enables the measurements of AC leakage 
currents, which could differ significantly from the DC Insulation test 
results.
Substitute leakage testing is performed at less than 40 V ac. and 
does not require a mains supply.

Substitute leakage testing is used for measuring protective 
conductor current and touch current, in addition to an insulation 
test, or where it is considered an insulation test may damage 
equipment.

The Substitute leakage test will not operate equipment and so 
can be used where the operation of the equipment under test is 
undesirable.

Portable RCD testing (PRCD)

Portable RCDs can be tested using the PAT150. There is no need 
to find a non-RCD protected supply as the PAT150 will not trip 
external RCDs.
Both 10 mA and 30 mA RCDs can be tested both for disconnection 
times and the manual test button function.

Separated Extra Low Voltage (SELV) supplies

SELV supplies should be tested to ensure the output voltage 
does not exceed maximum limits as defined in the international 
regulations for Extra Low voltage systems. The PAT150 permits up 
to 50 V ac measurement, with a PASS or fail indication for SELV.

Differential Leakage (Protective Conductor Current), Touch 
Current & operational test

The PAT150 includes the facility for mains powered leakage test. 
This test has the benefit that equipment under test will function 
during the test sequence.

Battery life

The PAT120 & PAT150 operates from AA Alkaline or NiMH cells. 
Battery life is typically 4 days, based on 120 assets per day.
The PAT150R can be re-charged with NiMH batteries fitted.

 www.megger.com

 Product 

 selection table:

UK

 

PAT120

PAT150

PAT150R

 Connector Interfaces

 

 Mains test socket

BS1363

 Power supply

 AA alkaline/NiMH

 Rechargeable (PAT150R)*

 

 

 Testing

 Protective 
 Earth Resistance

 250 V insulation

 500 V insulation

 

 Cable test

 Live protective 
 conductor current

 

 Live touch current

 

 Substitute leakage

 Functional test  (part 
 of Live leakage test)

 

 10 mA PRCD 

 

 30 mA PRCD

 

 SELV voltage

 

 Lead 
 resistance nulling

 

 Function keys

 Class 1

 Class 2

 Lead/cord

 PRCD

 

 Single test

 

 LCD Backlight

 Setup

 

 On/Off

 Standard accessories

 4mm plug lead probe 
 + croc clip

1

2

2

 Extension
 lead adaptor

 BS1363

 AC Charger Adaptor 

 

 

 Mains Supply Cord

 

 Carry case

Содержание 1003-062

Страница 1: ...PAT120 Series Portable Appliance Tester User Guide WWW MEGGER COM...

Страница 2: ...ION symbols 8 Carry strap fitting and removal 9 Switching ON OFF 10 Class I test PAT120 using substitute leakage 40 V ac 11 Class II test PAT120 Using Substitute Leakage 40 V ac 12 Power cord test PAT...

Страница 3: ...ured by Megger Instruments Limited Archcliffe Road Dover Kent CT17 9EN England Megger Instruments Limited reserves the right to change the specification of these instruments at any time without prior...

Страница 4: ...the Appliance tester During testing ensure no hazard will exist as a result of normal running or under fault conditions During testing the unit under test appliance should not be touched other than u...

Страница 5: ...tion Earth pin of the 230 V test socket will become hazardous if test lead P1 is in contact with hazardous voltages during continuity test Product Safety Category CATII 300 V MEASUREMENT CATEGORY II E...

Страница 6: ...PASS FAIL Neck strap slot Test groups Power ON Hold for 0 5s Backlight Main test socket Symbols used on the connection panel PAT120 connector panel G Do NOT connect P1 and P3 sockets to hazardous liv...

Страница 7: ...ive method 40 V ac leakage test for for touch current Battery powered test Cable polarity correct Power lead or Extension lead polarity test Live to Neutral cross polarity Test probe P1 to be connecte...

Страница 8: ...pment to be tested to the instrument Connect the P1 test lead to socket P1 on the Pat100 and the probe to exposed metalwork Ensure the probe is NOT connected to a 230V source Connect the P1 test lead...

Страница 9: ...www megger com 9 Carry strap fitting and removal Fitting the carry strap Removing carry strap...

Страница 10: ...Switching ON i ii iii PAT120 iv 0 5 s Switching OFF i Manual OFF ii Auto OFF 2 s Unit switches after 3 minutes of inactivity not adjustable Backlight Aborting a test A test can be aborted at any time...

Страница 11: ...be P1 is connected vi Remove probe P1 See note below vii viii Class I Pass NOTE If the contact symbol is displayed during the test the PAT has detected an open circuit load Ensure the appliance is swi...

Страница 12: ...on test 500 V OR Insulation test 250 V 2 s iv Ensure probe P1 is connected v Repeat contact on all exposed conductive parts vi See note below vii Class II Pass NOTE If the contact symbol appears the a...

Страница 13: ...www megger com 13 Power cord test PAT120 Testing a standard power cord i ii iii iv Insulation test 500 V OR Insulation test 250 V 2 s v vi...

Страница 14: ...www megger com 14 Extension lead test PAT120 Testing an extension lead or multi way extension lead i ii iii Insulation test 500 V OR Insulation test 250 V 2 s iv v vi vii...

Страница 15: ...idual test fail indicated by a small cross ii Overall FAIL indicated by a large cross Note Once an appliance has failed a test further testing of the test group sequence is prevented for safety reason...

Страница 16: ...5xI N10 ms PAT120 UK 0 2 0 2 0 2 1 2 1 3 5 0 25 NA NA NA NA PAT120 DE PAT120 CH PAT120 EU 0 3 0 3 0 3 1 2 1 3 5 0 5 NA NA NA NA International model variations Continuity retest after fail PAT120 DE CH...

Страница 17: ...e instrument They can be safely removed by ensuring all test leads have been disconnected from the instrument prior to removing the battery cover with a suitable screwdriver Spent PAT100 batteries are...

Страница 18: ...ltage 4V dc 0 10 open circuit Test current Bi directional 200mA 0 50mA into 2 load Continuity accuracy resistance 5 3 digits 0 to 19 99 Resistance resolution 10 m Display range 0 01 to 19 99 Test time...

Страница 19: ...2012 and IEC 61326 2 2 2005 FUSE user replaceable UK variants has mains plug fuse One F 100 mA 250 V 5 x 20 mm HBC fuse ENVIRONMENTAL Operating temperature range 0 C to 40 C Storage temperature range...

Страница 20: ...01 E ausales megger com Megger 4271 Bronze Way Dallas TX 75237 1017 U S A Tel 1 800 723 2861 U S A only Tel 1 214 330 3203 International Fax 1 214 337 3038 Megger Valley Forge Corporate Centre 2621 Va...

Страница 21: ...ontinuity insulation mains powered leakage testing and SELV measurements can be made using the Quick Test QT button Test group pass limits and test duration can be configured by the user Bond lead res...

Страница 22: ...ld be tested to ensure the output voltage does not exceed maximum limits as defined in the international regulations for Extra Low voltage systems The PAT150 permits up to 50 V ac measurement with a P...

Страница 23: ...Nominal mains frequency 50 Hz Test accuracy 5 3d 3uA A Resolution 0 01 mA Display range 0 10 to 19 99 mA Test duration User selectable from 2 sec to 5 seconds TOUCH CURRENT TEST Test voltage Nominal m...

Страница 24: ...arth bond lead 1001 233 SELV mains voltage test lead Red x1 1005 077 Extension lead adaptor BS1363 1001 234 Mains plug test lead 6231 601 Carry case 1005 075 Included accessories for PAT150R AC Mains...

Отзывы: