UP-PN-
II
v0.8 30
4.5.9 C
ONFIGURATION
COMMANDS
•
GS ] n1 n2 n3 (1D 5D Hex = 29 93 Dec)
Configuration command followed by 3 bytes n1 n2 n3.
n1 : - if n = 0 (00 hex) or n >=127 (7F hex)
Saves adjustments in flash memory.
Bytes n2 and n3 aren not necessary.
- value between 1 (01 hex) and quantity of groups
Selects the parameter group
n2 : Selects the field (01 hex to number of fields)
n3 : New value for the selected field.
- if multiple choices (01h to the quantity)
- if it is a number : a valid number in the range.
See the menu table for understand the groups, field and choices.
Attention:
Clock option is not available in this printer. This command is only
present for compatibility purpose
Example:
GS ] 03h 01h 08h
sets the serial group (Serial)
then the field “Baud” at the 8th choice, ie 9600 Baud.
The printer send on the interface :
Serial ->Baud =9600 Baud
GS ] 00h
saves parameters in flash memory.
The printer send :
FLASH CONFIGURATION
If a certain value is false, a specific error message is sent:
GROUP Out of range !
FIELD Out of range !
VALUE Out of range !
NOTHING TO FLASH !
Clock ->xxxxx =Not allowed !
Содержание UP-PN-II