P3V Veterinary Digital Ultrasonic Diagnostic Imaging System User Manual

 

- 14 

2.1.2.   Rear View 

 

Figure 2-2 Rear View 

1    Probe sockets 

2    Air Fan

 

3    AC power switch

 

4    Appliance inlet

 

5    Equipotential terminal

 

6    Handle

 

7    Probe holder

 

8    Coupling gel trough

 

9    Rechargeable lithium battery   

CAUTION 

1. 

To have  good  aeration  performance  and  be  able  to  operate normally,  please  don’t 
cover or plug the air fan or heat dissipation orifice partly or wholly by using any object. 

2.  For easy control, please don

’t cover or block the AC power switch using any object. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

 

 

 

 

Содержание P3V

Страница 1: ......

Страница 2: ...confidential information such as technical information and patent information are contained in this manual the user shall not disclose such information to any irrelevant third party The user shall und...

Страница 3: ...lt in personal animals injury or death CAUTION A CAUTION label advises against actions or situations that could damage equipment produce inaccurate data or invalidate a procedure NOTE A NOTE provides...

Страница 4: ...15 Chapter 3 Transportation and Storage 17 3 1 Moving the System 17 3 2 Storage 17 3 3 Transportation 17 Chapter 4 Installation Instructions 18 4 1 Environmental Requirements 18 4 2 Unpacking Inspecti...

Страница 5: ...Patient Information 60 6 3 Selecting an Examination Type 60 6 4 Activating and Deactivating a Probe 61 6 5 Selecting an Imaging Mode 62 6 6 Measurements and Calculations 62 6 6 1 Generic Measurements...

Страница 6: ...ric Report 98 8 9 Others 99 Chapter 9 Cardiology Measurement and Calculation 100 9 1 Cardiac Measurement and Calculation in M Mode 100 9 1 1 LV 104 9 1 2 Mitral Valve 106 9 1 3 Aortia 107 9 1 4 LVMW L...

Страница 7: ...General Technical Specifications 133 A1 6 Probe Specifications 134 A1 7 Operating Storage and Transportation Environment 135 A1 7 1 Operating Environment 135 A1 7 2 Storage and Transportation Environm...

Страница 8: ...t of Probe L743 2 153 A2 8 5 Test of Probe V563 2 157 A2 8 6 Test of Probe C321 2 161 Appendix III Measurement Accuracy 166 Appendix IV EMC Information Guidance and Manufacture s Declaration 167 Appen...

Страница 9: ...to your computer in the real time mode It has a 504 MB storage capacity Operation The folding keyboard designed with trackball is easy and convenient for various types of operation Generic Measurement...

Страница 10: ...s are considered during product design and production The following safety and preventive measures should be carried out WARNING 1 This equipment is not intended for treatment 2 The diagnosis and exam...

Страница 11: ...ded Refer to transducer use and care instructions Follow all infection control policies established by your office department or institution as they apply to personnel and equipment 13 Not intended fo...

Страница 12: ...of its service life 1 5 2 Biohazard Considerations WARNING 1 This device is not suitable for intracardiac use or direct cardiac contact 2 The manufacturer makes every effort to manufacture safe and ef...

Страница 13: ...el could remove the unit cover 8 Before use you must make sure that there is no visible evidence of damage on the equipment cables and probes which may affect patient safety or diagnostic capability T...

Страница 14: ...ied in Chapter 16 of IEC 60601 1 2005 or the multi socket is with an isolation transformer And the multi socket shall not be placed on the floor 22 SHOCK HAZARD Don t connect electrical equipment whic...

Страница 15: ...the equipment 9 The use of electrosurgical units or other devices that generate radio frequency interference may cause image distortion or other malfunction 10 Verify measurement results prior to ent...

Страница 16: ...ions Ultrasound machines are susceptible to Electromagnetic Interference EMI from radio frequencies magnetic fields and transients in the air of wiring Ultrasound machines also generate EMI The P3V co...

Страница 17: ...ttery to the electrical power outlet 9 Keep the battery away from fire and other heat sources 10 Do not use a damaged battery 11 Do not put the battery into a microwave oven or pressurized containers...

Страница 18: ...oid using the battery near the place where may cause static 8 Prevent the battery from children 9 Do not touch the battery s leaks that may make you uncomfortable If the leaks go into eyes do not knea...

Страница 19: ...ty 17 VGA output External Monitor 18 S Video Video output port 19 Fuse 20 Probe socket 21 Computer network 22 Foots witch To identify a footswitch or the connection for a footswitch 23 Protective eart...

Страница 20: ...n provided by enclosures IP Code temporary immersion For the probe but not including the probe connector 33 Power off on the system 34 Brightness 35 Contrast 36 Sound muting 37 Loudspeaker To adjust v...

Страница 21: ...ry Digital Ultrasonic Diagnostic Imaging System User Manual 13 Chapter 2 System Overview 2 1 Appearance 2 1 1 Front View Figure 2 1 Front View 1 Cable holder 2 Display screen 3 Control panel 4 I O por...

Страница 22: ...tential terminal 6 Handle 7 Probe holder 8 Coupling gel trough 9 Rechargeable lithium battery CAUTION 1 To have good aeration performance and be able to operate normally please don t cover or plug the...

Страница 23: ...pieces of fuse 5 20 T3 15AH250V 1 Netac U disk U180 2G 1 bottle of coupling gel 250 mL 1 Certificate of approval 1 Quick reference card 1 user manual 2 packing lists 2 2 2 Options The Digital Ultraso...

Страница 24: ...rea 96mm 72mm B W Paper size general display only one page 110mm 100mm Print area 99mm 74mm The USB printer output A4 paper 210 mm 297 mm Digital graphic printer110mm 18m Needle Guide Bracket Kit Mode...

Страница 25: ...the wheel caster brakes 6 Connect optional system accessories such as the single pedal footswitch 7 Secure the system and complete the system setup and then perform all the daily checking before usin...

Страница 26: ...uirements and methods WARNING 1 Do not use the device if it is found to be damaged or defective 2 Do not drop or collide with the probe Otherwise you shall give up using it 4 3 Connecting Procedure 1...

Страница 27: ...iece of packing foam on a flat ground 3 Carefully turn the main unit upside down and put it on the packing foam and assemble the screws to the main unit with a cross head screw driver as shown in figu...

Страница 28: ...lockwise to hide it and push the battery into place 4 Turn the flicker clockwise to keep the battery in place 5 Replace the battery cover Figure 4 3 Installing Battery to Main Unit To uninstall a batt...

Страница 29: ...of probe indicates the beginning direction of scanning The scan direction mark is shown below Figure 4 5 Probe Scan Direction Mark Schematic Diagram There is information about Model and SN on the prob...

Страница 30: ...r when the device is activated This is to avoid uncontrollable damage to the probe and the main unit NOTE Once the probe is connected to the main unit please do not reinstall it frequently This is to...

Страница 31: ...ufacturer to have an authorized representative or approved third party perform all on board connections of documentation and storage devices to the P3V Figure 4 7 Ports on the Left Panel Peripheral po...

Страница 32: ...is located at least 1 5 meters 1 8 meters in Canada and the U S A outside the patient environment A patient environment is defined as the area in which medical examination monitoring or treatment of t...

Страница 33: ...ter with the main unit by using a USB cable 3 Power on the main unit and run the printer If the printer can not work normally check the printer presetting see Section 5 7 3 General Presetting NOTE 1 M...

Страница 34: ...of the probe to click 2 Tighten the needle guide with the probe via the knob 3 Insert the needle along the guide hole Figure 4 9 Parts of Needle Guide of Convex Probe To install the needle guide of li...

Страница 35: ...P3V Veterinary Digital Ultrasonic Diagnostic Imaging System User Manual 27 Figure 4 10 Parts of Needle Guide of Linear Probe...

Страница 36: ...t via the power cable switch on the AC power switch on the rear panel Or Use the battery as the power supply 2 Press the power on off key on the top right control panel and a startup interface appears...

Страница 37: ...s contrast gain TGC dynamic range focus combination etc properly Adjusting the monitor s contrast and brightness is one of the most important factors for best image quality If theses controls are set...

Страница 38: ...mal information system date and time major parameter such as probe name probe frequency etc Gray map bar System menu Measurement result window Bottom status bar examination type operation prompt etc B...

Страница 39: ...tion controls 5 4 1 Trackball The trackball operation is easy and convenient It can achieve the following functions Move the measurement cursor during measurement Move to select menu items in menu bas...

Страница 40: ...T A SHIFT S SHIFT D SHIFT F SHIFT G SHIFT H French Characters Symbol Key Combination SHIFT Z SHIFT X SHIFT C SHIFT V SHIFT B SHIFT N Table 5 1 German and French Characters 5 4 4 Function Controls Key...

Страница 41: ...e displayed at the bottom of the screen Space key Space key Press this key in the annotation mode and comment mode to introduce a blank space on the cursor position Shift Shift Alphabetic key combinat...

Страница 42: ...key to freeze or unfreeze the B mode image Baseline adjusting keys Press these two keys to adjust the baseline in the PW mode Sample volume adjusting keys Press these two keys to adjust the sample vol...

Страница 43: ...s operation In comment mode press the key to delete the entered text one by one In parameter setting status press the key to decrease the parameter value Change Change key This key has dual functions...

Страница 44: ...ift the position of the current focus clockwise toward far field and counterclockwise toward near field When the light of focus number is on rotate the knob clockwise to increase the focus number and...

Страница 45: ...e after activating the PW angle adjustment function the rotation function is automatically activated and the rotation light is on You can rotate this button to adjust the arrow direction Footswitch Pe...

Страница 46: ...e rotation light is on You can rotate this button to adjust the arrow direction 4 Press Set to set the position of the arrow To move a comment 1 Move the cursor to a comment and there is a pane around...

Страница 47: ...he body mark dialog box and press Set to confirm the choice to add the body mark The selected body marks are displayed in the bottom left corner of the screen Reference Figure 5 1 Typical Image Screen...

Страница 48: ...Manual 40 To move a body mark 1 Move the cursor to a body mark Press Set button and there is a pane around the body mark 2 Press Set and move the cursor to a new position 3 Press Set to confirm the n...

Страница 49: ...ghtness or two dimensional 2D gray scale imaging NOTE To return to a real time B mode image from any imaging mode press B control This also deletes all measurements calculations comments or body marks...

Страница 50: ...s an M mode sweep The slope of this mode has four levels Pulsed Wave Doppler mode Display Control Press this key to switch between the B mode the B PW mode A pulsed wave Doppler PW scan produces a ser...

Страница 51: ...s you independently change the PW PRF When scanning in simultaneous mode both the 2D and the time series window receive data This feature lets you define which method is used based on the exam type Th...

Страница 52: ...ic Range Controls the overall contrast resolution of B mode Frame Persist Selects the number of frames for frame averaging to present a smoother softer image Line Persist Adjusts the line persist leve...

Страница 53: ...ns can be set using the Set and the Back keys 5 5 Menu Menus are displayed on the right of the screen Only one menu can be activated at a time The types are shown as follows System status menu In B mo...

Страница 54: ...e measurement and then the corresponding measurement cursor is displayed After entering B mode press Measure to display the menu below Figure 5 7 B Mode Generic Measurement and Calculation Menu Second...

Страница 55: ...play the secondary menu Ellipse and Trace Figure 5 8 Secondary Menu Figure 5 9 File Menu Figure 5 10 Needle Guide Menu 5 6 Dialog Box Operation The dialog box may have a few tabs as shown below You ca...

Страница 56: ...5 11 Labd Examination Presetting Dialog Box 5 7 Presetting 5 7 1 Entering and Exiting To activate presetting function 1 Press Preset and the system displays the preset menu as shown below Figure 5 12...

Страница 57: ...ng restarted 5 7 2 Displaying Modifying Presetting Parameters Select a type of preset and press Set to display the corresponding dialog box and you can modify the parameter following the prompt instru...

Страница 58: ...45s Set the interval of the cursor auto hiding Default Exam LAbd SAbd OB_Cannine OB_Feline OB_Equine OB_Bovine OB_Ovine OB_Other Muc Ten Sml Car Vas Preset the examination type Default Species Dog Ca...

Страница 59: ...ault comment color in inactive status Button F1 None save frame save image parameters save cine save AVI image file manager sweep speed PW invert wall filter Define the F1 key select one of the pull d...

Страница 60: ...and press Set to display obstetric examination presetting dialog box B M Parameter Tab Figure 5 15 Obstetric Presetting B M parameter Tab Item Setting Description Display B 2B 4B B M M PW Set display...

Страница 61: ...of Horizontal reversal V Reverse Null Set the attribute of Vertical reversal Table 5 6 Obstetric Presetting Information Parameter 1 PW Parameter Tab Figure 5 16 Obstetric Presetting PW Parameter Tab...

Страница 62: ...Select the default dynamic range for the examination in decibels dB During imaging the dynamic range can be adjusted in 4 increments Frame Persist 0 7 Set image frame correlation Rejection 0 7 Elimina...

Страница 63: ...0 degrees in B mode Table 5 9 Obstetric Presetting Information Others 5 7 5 Editing Comment Library There are eight tabs of comment library generic abdomen 1 abdomen 2 obstetric cardiac small parts le...

Страница 64: ...ith the keyboard Figure 5 20 User defined Comment Library 4 Roll the trackball to highlight the right side frame of User defined and press Set Then the cursor turns to as shown below You can enter som...

Страница 65: ...oftware perform the DICOM presetting as shown below Figure 5 22 DICOM Presetting Item Description System AE Title The same as the title set in the AE Title of Local Institution Name Set the name of th...

Страница 66: ...nd the server 2 Ensure that you have turned on the server before verifying it 5 7 9 Maintenance The maintenance can be only done by authorized personnel of the manufacturer 5 7 10 System Information I...

Страница 67: ...Printer begins to print Digital graphic printer 1 Connect the Digital graphic printer via the USB port 2 Check the printer referring to the printer user manual 3 Run the printer 4 Press Print of the w...

Страница 68: ...ation Press Patient Info to activate the patient data annotation function and then enter or edit the patient data as shown below Figure 6 1 Patient Data Input Dialog Box To close the input text box pr...

Страница 69: ...t and harmful interference to other devices in the environment may be caused Do not disconnect the probe in the unfreeze status The system limits patient contact temperature to 43 and the acoustic out...

Страница 70: ...rement function press Measure and the light will be on There is one type of mark in B mode measurement There are three types of marks in M mode measurement big and a line The measurement results will...

Страница 71: ...sheet Small Parts None General report Muscle None General report Tendon None General report Table 6 1 Examination Items and Results 6 6 1 Generic Measurements in B Mode In B mode highlight others and...

Страница 72: ...trackball to highlight Cir Area Then select Ellipse and press Set to activate a measurement cursor on the screen 3 Roll the trackball and press Set to anchor the start point of fixed axis of ellipse 4...

Страница 73: ...er is moved very near to the start point Or press Set to close the loop The system draws a line from the position of the active measurement marker to the beginning of the loop 5 Roll the trackball and...

Страница 74: ...and the minor axis of the cross section with the ellipse method 3 Unfreeze the system to acquire a new image vertical section image and then freeze it 4 Measure the length of the third axis in the ver...

Страница 75: ...e 1 Obtain a cross section image and freeze the system 2 Measure the length and the width 3 Unfreeze the system to acquire a new image vertical section image and then freeze it 4 Measure the height Yo...

Страница 76: ...easurement value and calculation result 5 During measurement you can press Change once to change the settled point and the active point if you press Change a second time the system interchanges the nu...

Страница 77: ...n result 5 During measurement you can press Change to change the start point and the end point if you press Change again the system interchanges the numerator and denominator 6 Roll the trackball and...

Страница 78: ...Roll the trackball and press Set to complete the measurement You can measure a maximum of one group of data The outcome will be displayed in the measurement result window 7 Press Measure to finish an...

Страница 79: ...measurement Histogram Freeze the image first before histogram measurement otherwise the prompt Image is not frozen please freeze and retry will pop up 1 Press Measure to activate measurement function...

Страница 80: ...press Set to anchor the start point and a big is displayed 4 Roll the trackball and press Set to anchor the end point 5 Roll the trackball and press Set to begin a new distance measurement You can me...

Страница 81: ...nchor the end point 5 Roll the trackball and press Set to begin a new slope measurement You can measure a maximum of four groups of data The outcome will be displayed in the measurement result window...

Страница 82: ...imum of four groups of data The outcome will be displayed in the measurement result window 6 Press Measure to finish and exit Figure 6 17 Heart Rate Measurement NOTE In B M PW mode you should define t...

Страница 83: ...ration Acceleration Vel1 Vel2 Interval 1 Press Measure to activate a measurement cursor 2 Roll the trackball to highlight Acceleration and press Set and a is displayed 3 Roll the trackball and press S...

Страница 84: ...ne only 2 Freeze the system before performing the tracing function To perform D Trace function manual tracing 1 Press Measure to activate a measurement cursor 2 Roll the trackball to highlight D Trace...

Страница 85: ...will be displayed in the measurement result window 7 Press Measure to finish and exit NOTE While automatic tracing you can add the envelope on the spectrum upwards or downwards The higher the sensitiv...

Страница 86: ...displayed on the bottom of the screen as shown below Figure 6 21 CINE Review Symbol To perform the CINE Review playback 1 Press Freeze to freeze the image and the system displays the cine menu as show...

Страница 87: ...rements of 5 f s 4 After opening a cine file you can perform measurements add comments and the body mark on the image and print them in the report See section 5 4 5 Comment function and section 5 4 6...

Страница 88: ...ss Quick Save on the keyboard Press Quick Save on the keyboard to save the current displaying image in BMP JPG FRM or DCM if DICOM is installed format set by File Type in the file menu as shown above...

Страница 89: ...ile menu to display the File Save As dialog box 2 Select a destination driver from the Driver pull down menu and a folder from the directory on the left or press New Folder to create a folder for stor...

Страница 90: ...of current driver Select a file format from the pull down menu such as BMP JPG DCM FRM CIN AVI DAT PDF to display files in one type or select to display all files Point to a file press Set to select i...

Страница 91: ...CIN files to DICOM server directly If the destination driver is local disk USB disk or portable hard disk press File Send to open the File Send dialog box select a target folder on the left or press...

Страница 92: ...een to open the previous image and to open the next image press to perform automatic browsing and press to stop automatic browsing press or Esc to exit 4 Press Open without selecting any file will ope...

Страница 93: ...splays the File Opening Dialog Box for selecting the driver 3 If the server is running normally all the DCM files of the selected driver will be sent to the server 4 The progress bar disappears after...

Страница 94: ...turer s control such with the change of tissue density bending of the needle off axis pressure by the person holding the probe may cause deflection of a needle outside of the displayed line even when...

Страница 95: ...ce highlight Angle in the needle guide menu and press Set to adjust and the system displays the angle 6 9 2 Calibrating Guide Line Performing Phantom Cal 1 Put the assembled puncture kit put the probe...

Страница 96: ...situation of puncture 2 Align the needle guide line with the target 3 Get the sample of the target 4 Move the probe away from the animal carefully WARNING Do not freeze the system when performing pun...

Страница 97: ...activate the application measurement function The measurement menu is displayed Figure 7 1 Abdominal Measurement and Calculation Menu Items of Measurement and Calculation CBD Gallbladder Left Kidney...

Страница 98: ...menu and then press Set 2 Measure KID L KID W or KID H by the method of distance measurement Reference Section 6 6 1 Generic Measurement in B mode 3 After the measurement the result of kidney will be...

Страница 99: ...n below Figure 7 2 Abdominal Worksheet The diagnosis editing column displays the cursor and you can enter diagnosis information To print the report Press Print in the Abdominal Worksheet Printing refe...

Страница 100: ...vate the application measurement function The system displays the measurement menu as shown in Figure 8 1 8 1 Obstetric Measurement and Calculation in B Mode Items of Measurement and Calculation CRL G...

Страница 101: ...matically and display the result 8 2 1 CRL To measure CRL 1 In the OB MEAS CAN menu roll the trackball to highlight the menu CRL press the Set key and move the cursor to image and display 2 Measure CR...

Страница 102: ...easured result window 4 To begin a new HD measurement repeat steps 1 through 3 You can measure a maximum of one group of data 8 2 4 BD To measure BD 1 In the OB MEAS CAN menu roll the trackball to hig...

Страница 103: ...calculate the MA automatically and display the result The measurements of HD and BD are the same to that of the Canine please refer to section 8 2 3 HD and 8 2 4 BD respectively for reference 8 4 Equ...

Страница 104: ...neric Measurement in B mode 3 The result is displayed in the measured result window 4 To begin a new GSD V measurement repeat steps 1 through 3 You can measure a maximum of one group of data 8 5 Bovin...

Страница 105: ...tems CRL BPD the system will calculate the MA automatically and display the result The measurement of CRL is the same to that of the Canine please refer to section 8 2 1 CRL for reference To measure B...

Страница 106: ...fter obstetric examination the system generates an obstetrical diagnosis worksheet automatically and the worksheet includes the information of the animal the measurements and calculations and the diag...

Страница 107: ...tions will not be displayed 2 You can check the measured items by opening the OB worksheet dialog box whenever you want during measurement or after that Then press OK or Cancel to close the dialog box...

Страница 108: ...Press to enter M mode Or press to enter B M mode and press Set to set the sample line 3 Press Measure to activate the application measurement function The system displays the measurement menu shown as...

Страница 109: ...e mm LVIDs Left Ventricle Internal Diameter ET Ejection Time Time ms or s HR Heart Rate M mode heart rate measurement or key in bpm EDV End Diastolic Volume EDV mL LVIDd3 mm3 1000 ESV End Systolic Vol...

Страница 110: ...000 EF Ejection fraction M mode EF No unit SV mL EDV mL 100 FS Fractional Shortening FS No unit LVIDd mm LVIDs mm LVIDd mm 100 SI Stroke Index SI No unit SV mL BSA m2 CI Cardiac Index CI No unit CO L...

Страница 111: ...Stoma Valve flow AVSV mL MAVO1 cm MAVO2 cm ET s 50 AA cm QMV Mitral Valve Flow QMV mL 4 DEV cm s DCT s Table 9 3 Other Measurement Items 4 Calculation items Label Description Method EDV End Diastolic...

Страница 112: ...ed on ESV and EDV which are calculated by LVIDs and LVIDd measurement respectively After measuring LVIDs and LVIDd and entering Heart Rate LVET and Height Weight the system can calculate some physiolo...

Страница 113: ...FS will be displayed in the measured result window To enter HR In the M cardiac measurement menu roll the trackball to highlight Input Then select the secondary menu Heart Rate and press Set to displ...

Страница 114: ...ight OK and press Set The measurements and calculations of all the LV parameters are as below Measurement or input items Input or measurement HR LVET and animal s Height Weight Measurement LVIDs and L...

Страница 115: ...procedure Roll the trackball to highlight Valve Volume and press Set Measure DEV The method is similar to the generic M mode slope measurement method Measure DCT The method is similar to the generic...

Страница 116: ...alculations are as below Measurement items LVPWd IVSTd and LVIDd The calculation formula LVMW g 1 04 IVSTd cm LVIDd cm LVPWd cm 3 LVIDd3 cm 3 13 6 LVMWI LVMW g BSA m 2 To calculate LVMW LVMWI 1 In the...

Страница 117: ...d end diastolic s end systolic Label Description Method LVLd Left Ventricle Long axle Diameter Distance mm LVALd Left Ventricle Area of Long axle Ellipse Area mm2 cm2 or dm2 LVLs Left Ventricle Long...

Страница 118: ...t Rate Key in bpm EDV End Diastolic Volume EDV mL 8 3 LVALd mm2 LVAMd mm2 LV IDd mm 1000 ESV End Systolic Volume ESV mL 8 3 LVALs mm2 LVAMs mm2 LV IDs mm 1000 SV Stroke volume SV mL EDV mL ESV mL CO C...

Страница 119: ...ulate by the selected formula m2 Table 9 8 Measurement and Calculation Items with Bullet Formula 4 Modified SIMPSON formula NOTE d end diastolic s end systolic Label Description Method LVAMd Left Vent...

Страница 120: ...No unit LVIDd mm LVIDs mm LVIDd mm x 100 MVCF Mean Velocity Circumferential Fiber Shortening MVCF No unit LVIDd mm LVIDs mm LVIDd mm x ET ms 1000 Table 9 10 Other Measurement and Calculation Items 9 2...

Страница 121: ...e B cardiac measurement menu roll the trackball to highlight Input Then select the secondary menu Heart Rate and press Set to display an HR input dialog box as shown below Figure 9 6 HR Input Dialog B...

Страница 122: ...n Height and Weight To calculate CI and SI 1 In the B cardiac measurement menu roll the trackball to highlight Input Then select the secondary menu Height Weight and press Set to display a Height and...

Страница 123: ...lease enter B M mode or M mode cardiac measurement The result of ventricle volume measurement is more exact in two dimension You can get the two dimension heart image of end diastolic and end systolic...

Страница 124: ...the trackball and press Set to begin a new PS ED measurement You can measure a maximum of one group of data The outcome will be displayed in the measurement result window as shown below 9 4 Cardiac R...

Страница 125: ...tal Ultrasonic Diagnostic Imaging System User Manual 117 To print the report Press Print in the Cardiac Worksheet Printing reference Section 5 8 Printing 9 5 Others Select Others to enter another appl...

Страница 126: ...ication measurement function The system displays the measurement menu as shown below Items of Measurement and Calculation Velocity Forelimb Hindimb CCA ICA ECA and Vert A Figure 10 1 Vascular Measurem...

Страница 127: ...Generic Measurement in PW mode 3 The results are displayed in measurement result window 4 To begin a new Hindlimb measurement repeat steps 1 through 3 You can measure a maximum of one group of data 1...

Страница 128: ...esult window 4 To begin a new ECA measurement repeat steps 1 through 3 You can measure a maximum of one group of data 10 1 6 Vert A To measure Vert A 1 In the PW vascular measurement menu select Vert...

Страница 129: ...re 10 2 Vascular Worksheet The diagnosis editing column displays the cursor and you can enter diagnosis information To print the report Press Print in the vascular worksheet Printing reference Section...

Страница 130: ...all the probes Do not use any damaged probe Visually inspect all the probe assembly cables and associated connectors Visually inspect all the power cords Do not turn on the power if a cord is frayed...

Страница 131: ...ed and qualified personnel WARNING 1 To avoid electrical shock and damage to the system always shut down and disconnect the device from the AC power source before cleaning and disinfection 2 To avoid...

Страница 132: ...of polarizer is very soft and easily scratched 11 2 2 Probe and Probe Holder Cleaning and Disinfection To clean probe holder 1 Disassemble the probe holder by uninstalling the two screws 2 Wash the ho...

Страница 133: ...ng to the disinfectant instructions Flush all residues from the probe and perform air dry WARNING 1 Do not immerse the probe connector If the cable connector is immersed do not plug the connector into...

Страница 134: ...n the head of the probe and it should be wiped off after use Each time after use clean and disinfect the probe The acoustical window and the shell of the probe should be examined frequently WARNING Th...

Страница 135: ...completely dry Figure 11 2 Assembling and Disassembling Trackball CAUTION Do not drop or place foreign objects inside the trackball assembly or it may affect the trackball operation and damage the sy...

Страница 136: ...s with the same model as the manufacturer specified 11 2 6 Disinfectants Disinfectants chemical name Disinfectants trade name Probe Glutaraldehyde 2 4 Cidex Activated Dialdehyde Solution 2 4 Ortho Pht...

Страница 137: ...experience to perform these tests Inspect the safety related labels for legibility Inspect the fuse to verify compliance with rated current and breaking characteristics Verify that the device function...

Страница 138: ...knob 2 Strip shape or snowflake shape disturbance occurs on the display screen 1 Inspect the power supply 2 Check whether it is disturbed by the ignition action of any other device 3 Check the distur...

Страница 139: ...by anyone not authorized by the manufacturer d Damage caused by accidents e Replacement or removal of serial number label and manufacture label If a product covered by this warranty is determined to...

Страница 140: ...Probe do not include the probe connector IPX7 Footswitch optional IPX8 According to the degree of safety of application in the presence of a flammable gas Equipment not suitable for use in the presenc...

Страница 141: ...el Number 1024 768 Center Luminance of White Typ 450 cd m2 Contrast Ratio Typ 700 A1 5 General Technical Specifications Display Modes B 2B 4B B M M and PW Image Gray Scale 256 levels Image Magnificati...

Страница 142: ...leration trace and RI Annotations Patient name age sex time date hospital name doctor name comment full screen character editing Body Mark 40 ypes USB Port USB 2 0 A1 6 Probe Specifications This devic...

Страница 143: ...cs abdomen cardiology Large animal cardiology Small animal obstetrics abdomen cardiology Large animal cardiology NOTE Maximum transducer temperature rise during use Less than 10 C Expanded uncertainty...

Страница 144: ...ly low with Transcranial Doppler it is important to know how to control and limit patient exposure Major governing bodies in ultrasound have issued statements to the effect that there are no known adv...

Страница 145: ...l Index Cavitations will be generated when ultrasound wave passes through and contacts tissues resulting in instantaneous local overheating This phenomenon is determined by acoustic pressure spectrum...

Страница 146: ...The MI value of this system is lower than 1 0 and it is not displayed The TI values in the upper right part of the screen In PW mode the TI value is displayed and the start point is 0 1 The operator s...

Страница 147: ...5 percents for pressure Based on the stated accuracy of the 8 bit resolution of the Agilent DSO6012A Digital Oscilloscope and the signal to noise ratio of the measurement 3 Temperature 1 percent Based...

Страница 148: ...the most effective for all the transducers A2 6 Prudent Use Statement Although no confirmed bioeffects on patients caused by exposure from present diagnostic ultrasound equipment have ever been repor...

Страница 149: ...on scan Aaprt 1 Aaprt 1 Global Maximum Index Value 0 67 0 10 0 41 Associated Acoustic Parameters Pr 3 MPa 1 15 W0 mW 30 80 30 80 Min of W 3 z1 ITA 3 z1 mW Z1 cm Zbp cm Zsp cm z PII 3max cm 5 19 deq Zs...

Страница 150: ...0 0107 Associated Acoustic Parameters Pr 3 MPa 1 08 W0 mW 0 802 0 802 Min of W 3 z1 ITA 3 z1 mW 0 42 Z1 cm 3 28 Zbp cm 2 816 Zsp cm 5 06 z PII 3max cm 5 50 deq Zsp cm 1 92 fc MHz 2 90 2 90 2 90 2 90...

Страница 151: ...coustic Parameters Pr 3 MPa 1 08 W0 mW 31 602 31 602 31 602 Min of W 3 z1 ITA 3 z1 mW 0 42 Z1 cm 3 28 Zbp cm 2 816 Zsp cm 5 06 z PII 3max cm 5 50 deq Zsp cm 1 92 fc MHz 2 90 2 90 2 90 2 90 2 90 Dim of...

Страница 152: ...Associated Acoustic Parameters Pr 3 MPa 0 92 W0 mW 57 53 57 53 Min of W 3 z1 ITA 3 z1 mW 33 92 Z1 cm 2 82 Zbp cm 2 816 Zsp cm 4 94 z PII 3max cm 5 45 deq Zsp cm 0 013 fc MHz 2 71 2 71 2 71 2 71 Dim o...

Страница 153: ...Global Maximum Index Value 0 78 0 11 0 26 Associated Acoustic Parameters Pr 3 MPa 1 77 W0 mW 7 443 7 443 Min of W 3 z1 ITA 3 z1 mW Z1 cm Zbp cm Zsp cm z PII 3max cm 1 60 deq Zsp cm fc MHz 5 08 5 08 5...

Страница 154: ...0141 0 0126 Associated Acoustic Parameters Pr 3 MPa 1 71 W0 mW 0 3547 0 3547 0 3547 Min of W 3 z1 ITA 3 z1 mW Z1 cm Zbp cm Zsp cm 1 40 z PII 3max cm 1 64 deq Zsp cm 1 63 fc MHz 5 09 5 09 5 09 5 09 Di...

Страница 155: ...iated Acoustic Parameters Pr 3 MPa 1 71 W0 mW 7 7977 7 7977 7 7977 7 7977 Min of W 3 z1 ITA 3 z1 mW Z1 cm Zbp cm Zsp cm 1 40 z PII 3max cm 1 64 deq Zsp cm 1 63 fc MHz 5 09 5 09 5 09 5 09 5 09 Dim of A...

Страница 156: ...1 07 0 49 Associated Acoustic Parameters Pr 3 MPa 1 65 W0 mW 13 80 13 80 13 80 Min of W 3 z1 ITA 3 z1 mW Z1 cm Zbp cm Zsp cm 1 36 z PII 3max cm 1 46 deq Zsp cm 0 021 fc MHz 4 97 4 97 4 97 4 97 Dim of...

Страница 157: ...aprt 1 Global Maximum Index Value 0 50 0 02 0 06 Associated Acoustic Parameters Pr 3 MPa 1 15 W0 mW 2 694 2 694 Min of W 3 z1 ITA 3 z1 mW Z1 cm Zbp cm Zsp cm z PII 3max cm 1 58 deq Zsp cm fc MHz 5 18...

Страница 158: ...0061 0 0028 Associated Acoustic Parameters Pr 3 MPa 1 22 W0 mW 0 1272 0 1272 Min of W 3 z1 ITA 3 z1 mW 0 067 Z1 cm 1 74 Zbp cm 1 727 Zsp cm 1 74 z PII 3max cm 1 60 deq Zsp cm 4 20 fc MHz 5 29 5 29 5 2...

Страница 159: ...iated Acoustic Parameters Pr 3 MPa 1 22 W0 mW 2 8212 2 8212 2 8212 Min of W 3 z1 ITA 3 z1 mW 0 067 Z1 cm 1 74 Zbp cm 1 727 Zsp cm 1 74 z PII 3max cm 1 60 deq Zsp cm 4 20 fc MHz 5 29 5 29 5 29 5 29 5 2...

Страница 160: ...50 0 12 Associated Acoustic Parameters Pr 3 MPa 0 97 W0 mW 5 461 5 461 Min of W 3 z1 ITA 3 z1 mW 2 806 Z1 cm 1 74 Zbp cm 1 727 Zsp cm 1 74 z PII 3max cm 1 50 deq Zsp cm 0 053 fc MHz 5 54 5 54 5 54 5...

Страница 161: ...rt 1 Global Maximum Index Value 0 67 0 04 0 13 Associated Acoustic Parameters Pr 3 MPa 1 49 W0 mW 4 56 4 56 Min of W 3 z1 ITA 3 z1 mW Z1 cm Zbp cm Zsp cm z PII 3max cm 1 96 deq Zsp cm fc MHz 4 99 4 99...

Страница 162: ...0 0095 0 0065 Associated Acoustic Parameters Pr 3 MPa 1 51 W0 mW 0 2278 0 2278 0 2278 Min of W 3 z1 ITA 3 z1 mW Z1 cm Zbp cm Zsp cm 1 84 z PII 3max cm 2 04 deq Zsp cm 2 41 fc MHz 5 06 5 06 5 06 5 06 D...

Страница 163: ...ciated Acoustic Parameters Pr 3 MPa 1 51 W0 mW 4 7878 4 7878 4 7878 4 7878 Min of W 3 z1 ITA 3 z1 mW Z1 cm Zbp cm Zsp cm 1 84 z PII 3max cm 2 04 deq Zsp cm 2 41 fc MHz 5 06 5 06 5 06 5 06 5 06 Dim of...

Страница 164: ...5 0 71 0 27 Associated Acoustic Parameters Pr 3 MPa 1 32 W0 mW 9 527 9 527 9 527 Min of W 3 z1 ITA 3 z1 mW Z1 cm Zbp cm Zsp cm 1 66 z PII 3max cm 2 04 deq Zsp cm 0 032 fc MHz 5 59 5 59 5 59 5 59 Dim o...

Страница 165: ...imum Index Value 0 66 0 04 N A Associated Acoustic Parameters Pr 3 MPa 1 30 W0 mW 10 51 N A Min of W 3 z1 ITA 3 z1 mW Z1 cm Zbp cm Zsp cm z PII 3max cm 2 96 deq Zsp cm fc MHz 3 91 3 91 N A Dim of Aapr...

Страница 166: ...ated Acoustic Parameters Pr 3 MPa 1 18 W0 mW 0 28 N A Min of W 3 z1 ITA 3 z1 mW 0 142 Z1 cm 2 50 Zbp cm 2 545 Zsp cm 2 68 z PII 3max cm 3 02 deq Zsp cm 3 48 fc MHz 3 90 3 90 3 90 N A Dim of Aaprt X cm...

Страница 167: ...eters Pr 3 MPa 1 18 W0 mW 10 79 10 79 N A Min of W 3 z1 ITA 3 z1 mW 0 142 Z1 cm 2 50 Zbp cm 2 545 Zsp cm 2 68 z PII 3max cm 3 02 deq Zsp cm 3 48 fc MHz 3 90 3 90 3 90 3 90 N A Dim of Aaprt X cm 1 512...

Страница 168: ...d Acoustic Parameters Pr 3 MPa 1 04 W0 mW 21 59 N A Min of W 3 z1 ITA 3 z1 mW 10 74 Z1 cm 2 50 Zbp cm 2 545 Zsp cm 2 50 z PII 3max cm 2 90 deq Zsp cm 0 024 fc MHz 3 95 3 95 3 95 N A Dim of Aaprt X cm...

Страница 169: ...um Index Value 0 69 0 21 N A Associated Acoustic Parameters Pr 3 MPa 1 18 W0 mW 31 22 N A Min of W 3 z1 ITA 3 z1 mW Z1 cm Zbp cm Zsp cm z PII 3max cm 2 60 deq Zsp cm fc MHz 2 92 2 92 N A Dim of Aaprt...

Страница 170: ...oustic Parameters Pr 3 MPa 1 08 W0 mW 13 10 N A Min of W 3 z1 ITA 3 z1 mW 15 48 Z1 cm 2 60 Zbp cm 2 67 Zsp cm 2 60 z PII 3max cm 2 61 deq Zsp cm 0 47 fc MHz 2 85 2 85 2 85 N A Dim of Aaprt X cm 1 9152...

Страница 171: ...3 MPa 1 08 W0 mW 26 20 26 20 N A Min of W 3 z1 ITA 3 z1 mW 15 48 Z1 cm 2 60 Zbp cm 2 67 Zsp cm 2 60 z PII 3max cm 2 61 deq Zsp cm 0 47 fc MHz 2 85 2 85 2 85 2 85 N A Dim of Aaprt X cm 1 9152 1 9152 1...

Страница 172: ...oustic Parameters Pr 3 MPa 1 40 W0 mW 119 5 N A Min of W 3 z1 ITA 3 z1 mW 68 62 Z1 cm 2 60 Zbp cm 2 67 Zsp cm 2 60 z PII 3max cm 2 60 deq Zsp cm 0 48 fc MHz 3 00 3 00 3 00 N A Dim of Aaprt X cm 1 9152...

Страница 173: ...al PII Ipi Pulse intensity Integral deq Zsp deq Zb Equivalent Beam Diameter at the point of Zsp fc fawf Center Frequency Acoustic Working Frequency X X 12dB Output Beam Dimensions Y Y PD td Pulse Dura...

Страница 174: ...Distance depth up to 324 mm 5 Area Trace up to 720 cm2 10 Area Ellipse up to 720 cm2 8 Angle 0 to 180 3 Ratio A B Result B A and A B A Result A B up to 1 0 1 0 to 99 9 10 of A 10 of A Time Motion TM M...

Страница 175: ...missions are very low and are not likely to cause any interference in nearby electronic equipment RF emissions CISPR 11 Class A The P3V is suitable for use in all establishments other than domestic an...

Страница 176: ...teristic of a typical location in a typical commercial or hospital environment Voltage dips short interruptions and voltage variations on power supply input lines IEC 61000 4 11 5 UT 95 dip in UT for...

Страница 177: ...anufacturer and d is the recommended separation distance in metres m Field strengths from fixed RF transmitters as determined by an electromagnetic site survey a should be less than the compliance lev...

Страница 178: ...ding to the maximum output power of the communications equipment Rated maximum output power of transmitter W Separation distance according to frequency of transmitter m 150kHz 80MHz d P 2 1 80MHz 800M...

Страница 179: ...et Kit BGK CR60 02 01 102338 Needle Guide Bracket Kit BGK LA43 02 01 102355 Needle Guide Bracket Kit BGK LA70 02 01 102899 Needle Guide Bracket Kit BGK MCR10 02 01 116248 Needle Guide Bracket Kit BGK...

Страница 180: ...iameter Transverse Trunk Diameter APAD Antero Posterior Abdominal Diameter CER Cerebellum Diameter FTA Fetus Trunk cross section Area HUM Humerus Length OFD Occipital Frontal Diameter THD Thorax Diame...

Страница 181: ...e Stoma Valve flow QMV Mitral Valve Flow LVLd Left Ventricle Long axle Diameter end diastolic LVALd Left Ventricle Area of Long axle end diastolic LVLs Left Ventricle Long axle Diameter end systolic L...

Страница 182: ...THY H Right Thyroid Gland Height Urology RUV Residual Urine Volume mL or L RUV L Residual Urine Length RUV W Residual Urine Width RUV H Residual Urine Height PV Prostate Volume mm3 cm3 or dm3 PV L Pr...

Страница 183: ......

Отзывы: