Sentinel 100 - Hardware Installation Guide
30
media5corp.com
Note:
Do not release the
Reset/Default
button before the LEDs stop blinking and are steadily ON.
This can take up to 30 seconds.
4)
Release the paper clip.
Result
All configuration parameters are reset to their default value. When the Mediatrix unit has finished
its provisioning sequence, it is ready to be used with a DHCP server provided IP address and MIB
parameters. This procedure can also be performed at run time.
Disabling the Rescue Interface
Information
By default the Rescue interface is disabled. However, after a partial reset the rescue interface is
enabled.
Steps
1)
Go to
Management
/
Misc
.
2)
From the
Network Interface
drop-down menu, select the interface that will be used to
manage the unit.
Note:
If you keep the
Rescue Interface
selected, you will not be able to get into the management
interface after disabling it.
3)
Go to
Network
/
Interfaces
.
4)
In the
Rescue Interface
table, from the
Activation
selection list, select
Disable
.
5)
Click
Apply
.
Result