Sentinel 100 - Hardware Installation Guide
29
media5corp.com
Result
The Rescue Network Interface is displayed when accessing the Management Interface. Several
parameters and services are modified.
What to do next
Remove the changes in your configuration that caused the system to no longer respond, and
do not forget to disable the Rescue Network interface (
Network
/
Interfaces
/
Rescue Network
Configuration
table).
Factory Reset
The Factory reset reverts the Mediatrix unit back to its default factory settings.
It deletes the persistent configuration parameters of the unit, including:
•
User files stored in the File service
•
Certificates, except for factory installed ones
•
Log files of the File service
The Factory reset should be performed with the Mediatrix unit connected to a network with access
to a DHCP server. If the unit cannot find a DHCP server, it will sent requests indefinitely. A Factory
Reset can be triggered either:
•
Directly on the unit. Refer to
Performing a Factory Reset (p. 29)
.
•
Via the web interface of the Mediatrix unit (
Management
/
Firmware Upgrade
).
•
Via the Command Line Interface of the Mediatrix unit by using the
fpu.defaultsetting
parameter.
Performing a Factory Reset
Information
The Factory reset alters any persistent configuration data of the Mediatrix unit.
Note:
The Mediatrix unit must be connected to a network with access to a DHCP server. If the unit
cannot find a DHCP server, it will send requests indefinitely.
Steps
1)
Power the Mediatrix unit Off.
2)
Insert a small, unbent paper clip into the
Reset/Default
hole located at the rear of the
Mediatrix unit.
3)
While pressing the
Reset/Default
button, restart the unit.