Sentinel 100 - Hardware Installation Guide
26
media5corp.com
LED state
Description
Power LED blinking green 3 cycles per second,
50% duty.
Waiting for DHCP (IPv4 or IPv6) answer or IPv6
router advertisement or PPPoE connection. No Ip
Address configured.
Ready LED OFF, all other LEDs cycling from
right to left, left to right.
The unit tries to download and install a firmware
given by the Network Rescue server.
RESET/DEFAULT Button
The
Reset/Default
switch can be used to perform a partial or factory reset while the unit is running.
In other words, the
Reset/Default
switch can be used to:
•
Cancel an action that was started.
•
Revert to known factory settings if the Mediatrix unit refuses to work properly for any reason
or the connection to the network is lost.
•
Reconfigure a unit.
The
Reset/Default
switch will generate different actions depending on the amount of time the
button is held.
Pressing Time
Action
Comment
LED Pattern
2 to 6 seconds
Restarts the Mediatrix
unit.
No changes are made
to the Mediatrix unit
settings.
Power1 blinking, all
other LEDs OFF
7 to 11 seconds
Initiates a Partial Reset
of the Mediatrix unit.
Restarts the unit in a
known and static state
while keeping most
of the configuration
unchanged.
All LEDs blinking,
1cycle per second, 50%
duty
12 to 16 seconds
Initiates a Factory
Reset of the Mediatrix
unit.
Reverts the unit back
to its default factory
settings.
All LEDs steady ON
17 seconds and more
No action is taken.
This is useful if you
accidentally pushed
the button and do not
need and action to be
applied.
The action is ignored.
N/A