3
2.2
Features
2
l
without Neutral
3φ3-wire
/ 340~530VAC wide input range
l
High efficiency up to 9 %
7
l
Water/ forced air cooling
selectable
l
Built-in CAN bus/Optional PMBus/Modbus-RTU/RS-485 protocol
l
Output voltage and constant current level programmable
l
(
)
40KW
Active current sharing up to 4 units
l
Built-in remote ON-OFF control/ auxiliary power/ alarm signal
l
Protections: Short circuit/ Overload/ Over voltage/ Over temperature/
Fan fail
l
5 years warranty
4
2
2.3
Specification
SHP-10K-55
SHP-10K-115
SHP-10K-230
SHP-10K-380
MODEL
OUTPUT
INPUT
ENVIRON-
MENT
PROTECTION
FUNCTION
DC VOLTAGE (factory default)
55V
115V
230V
380V
131A
87A
43.5A
26.3A
0 ~ 150A
0 ~ 87A
0 ~ 46.3A
0 ~ 30A
7200W
10000W
10000W
10000W
48 ~ 57.6V
115 ~ 138V
216 ~ 260V
334 ~ 400V
0.3Vp-p
0.6Vp-p
1Vp-p
1Vp-p
Can be adjusted via built-in potentiometer
39 ~ 57.6V
90 ~ 138V
145 ~ 166V
170 ~ 260V
273 ~ 312V
260 ~ 400V
420 ~ 480V
±
1.0%
±
1.0%
±
1.0%
±
1.0%
±
0.5%
±
0.5%
±
0.5%
±
0.5%
±
0.5%
±
0.5%
±
0.5%
±
0.5%
3000ms, 100ms at full load
25ms / 400VAC at 75% load 20ms / 400VAC at full load
3
3-wire / 340 ~ 530VAC
ψ
-30 ~ +
")
70
(Refer to “Derating Curve
℃
47 ~ 63Hz
20 ~ 90% RH non-condensing
≧
0.98/400VAC/480VAC at full load
-40 ~ +85
, 10 ~ 95% RH non-condensing
℃
94.5%
96%
96.5%
96.5%
±
℃
℃)
0.03%/
(0 ~ 50
11.2A/400VAC 9.5A/480VAC 15.7A/400VAC 13A/480VAC
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
40A/400VAC 65A/480VAC
<6.5mA peak / 530VAC
100 ~ 105% of rated current
Protection type : Constant current limiting, unit will shutdown after 5 sec. re-power on to recover
60.5 ~ 69.1V
Protection type :Shut down O/P voltage,re-power on to recover
Shut down O/P voltage, recovers automatically after temperature goes down
Up to 4 units. Please refer to the Function Manual
12V@1A tolerance
5%, ripple 150mVp-p
±
Please refer to the Function Manual
AC-OK, DC-OK, Fan Fail. Please refer to the Function Manual.
The TTL signal output, PSU turn on = -0.5 ~ 0.5V ; PSU turn off = 3.5 ~ 5.5V
Please refer to the Function Manual
Adjustment of output voltage is allowable to between 50 ~ 120% of nominal output voltage
Please refer to the PV curve Function Manual
Adjustment of constant current level is allowable to between 20 ~ 100% of rated current
Please refer to the PC curve Function Manual
CURRENT (factory default)
RATED RANGE
RATED POWER (max.)
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
WORKING TEMP.
FREQUENCY RANGE
WORKING HUMIDITY
POWER FACTOR (Typ.)
STORAGE TEMP., HUMIDITY
EFFICIENCY (Typ.)
TEMP. COEFFICIENT
AC CURRENT (Typ.)
VIBRATION
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
OVERLOAD
OVER VOLTAGE
OVER TEMPERATURE
CURRENT SHARING
AUXILIARY POWER(AUX)
REMOTE ON-OFF CONTROL
ALARM SIGNAL OUTPUT
DC-OK SIGNAL
OUTPUT VOLTAGE
PROGRAMMABLE
CONSTANT CURRENT
LEVEL PROGRAMMABLE
FULL POWER VOLTAGE RANGE
RIPPLE & NOISE (max.)
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE
Note.2
Note.3
Note.4
Note.6