49
byte1:
Bit 0:3 VIN Factor:
The Factor of AC input voltage
0x0=
AC input relevant commands not supported
0x4=0.001
0x5=0.01
0x6=0.1
0x7=1.0
0x8=10
0x9=100
0xA~0xF= Reserved
Bit 4:7 FAN_SPEED Factor:
The Factor of fan speed
0x0=
Fan speed relevant commands not supported
0x4=0.001
0x5=0.01
0x6=0.1
0x7=1.0
0x8=10
0x9=100
0xA~0xF= Reserved
byte2:
Bit 0:3 TEMPERATURE_1 Factor:
The Factor of internal ambient temperature
0x0=internal ambient temperature relevant commands not supported
0x4=0.001
0x5=0.01
0x6=0.1
0x7=1.0
0x8=10
0x9=100
0xA~0xF= Reserved
6
50
◎
SYSTEM_STATUS (0x00C3)
:
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
Low byte
PFC OK
_
-
-
EEPER
INITIA-
LSTATE
ADL_ON
DC_OK
M S
/
Bit 1 DC_OK:Secondary DD output voltage status
0=Secondary DD output voltage status TOO LOW
1=Secondary DD output voltage status NORMAL
Bit 2: PFC_OK:Primary PFC status
0=Primary PFC OFF or abnormal
1=Primary PFC ON normally
Bit 4 ADL_ON:Active dummy load control status
0=Active dummy load off/function not supported
1=Active dummy load on
Bit 5 INITIAL_STATE:Device initialized status
0=In initialization status
1=NOT in initialization status
Bit 6 EEPER:EEPROM data access error
0=EEPROM data access normal
1=EEPROM data access error
Note: Unsupported settings displays with "0"
SYSTEM_CONFIG (0x00C4):
Bit7
Bit6
Bit5
Bit4
Bit3
Bit2
Bit1
Bit0
Low byte
-
-
-
-
-
OPERATION_INI MOD_CTRL
Low byte:
Bit 0
_CTRL:Modbus communication control status
MOD
=The output voltage/current defined by control over SVR/PV/PC
0
1=The output voltage, current, ON/OFF control defined by control over
Modus (VOUT_SET, IOUT_SET, OPERATION)
Bit 0: M/S:parallel mode status
0=Current device is Slave
1=Current device is Master