background image

29

Table 6-2

The command list of the SHP-10K is shown in Table 6-2. It is
compliant with the standard protocol of PMBus Rev. 1.1.For
detailed information, please refer to PMBus official website

(

http://pmbus.org/specs.html).

6 1 2

. .

PMBus Command List

Command

Code

01h

00h

02h

19h

20h

21h

# of data

Bytes

1

1

1

1

1

2

Description

Remote ON/OFF control

Page

ON/OFF function configuration

Capabilities of a PMBus device

Define data format for output voltage

(format: linear, N= -6)

Define data format for output voltage

Output voltage trimmed value

Output overcurrent setting value

(format: linear, N= -2)

Output voltage reading value

(format: linear, N= -6)

Output current reading value

(SHP-10K: format: linear, N= -2)

Command

Name

OPERATION

PAGE

ON_OFF_CONFIG

CAPABILITY

VOUT_MODE

VOUT_COMMAND

Transaction

Type

Page

R/W Byte

R/W Byte

All

All

All

All

All

All

All

All

All

All

All

All

All

All

All

All

All

All

All

All

All

All

All

All

All

All

All

All

All

All

All

0

0

1

1

2

2

Read Byte

Read Byte

Read Byte

22h

2

VOUT_TRIM

R/W Word

R/W Word

47h

79h

7Ah

7Bh

7Ch

7Dh

1

2

1

1

1

1

Define protection and response when an
output overcurrent fault occurred

Summary status reporting

Output voltage status reporting

Output current status reporting

AC input voltage status reporting

Temperature status reporting

IOUT_OC_FAULT_RESPONSE

STATUS_WORD

STATUS_VOUT

STATUS_IOUT

STATUS_INPUT

STATUS_TEMPERATURE

Read Byte

Read Word

Read Byte

Read Byte

Read Byte

Read Byte

Read Byte

Read Byte

Read Byte

7Eh

1

Communication, logic, Memory status reporting

STATUS_CML

46h

2

IOUT_OC_FAULT_LIMIT

R/W Word

80h

81h

88h

88h

88h

89h

89h

89h

8Bh

8Ch

1

1

2

2

2

2

2

2

2

2

Manufacture specific status reporting

Fan1 and 2 status reporting

V

RS

input voltage reading value

(

, =0)

format: linear N

V

ST

input voltage reading value

(

, =0)

format: linear N

V

TR

input voltage reading value

(

, =0)

format: linear N

R

input current reading value

(

, = )

format: linear N -5

S

input current reading value

(

, = )

format: linear N -5

T

input current reading value

(

, = )

format: linear N -5

STATUS_MFR_SPECIFIC

STATUS_FANS_1_2

READ_VIN

READ_VIN

READ_VIN

READ_IIN

READ_IIN

READ_IIN

READ_VOUT

READ_IOUT

Read Word

Read Word

Read Word

Read Word

Read Word

Read Word

Read Word

Read Word

98h

1

The compliant revision of the PMBus

PMBUS_REVISION

Read Byte

8Dh

2

Temperature 1 reading value

(format: linear, N= -3)

READ_TEMPERATURE_1

Read Word

99h

90h

91h

9Ah

9Bh

9Ch

9Dh

9Eh

BEh

BFh

12

2

2

12

24

3

6

12

2

2

Manufacturer's name

Fan speed 1 reading value

Fan speed 2 reading value

Manufacturer's model name

Firmware revision

Manufacturer's factory location

Manufacture date

Product serial number

System setting

System status

MFR_ID

READ_FAN_SPEED_1

READ_FAN_SPEED_2

MFR_MODEL

MFR_REVISION

MFR_LOCATION

MFR_DATE

MFR_SERIAL

SYSTEM_CONFIG

SYSTEM_STATUS

Block Read

Read Word

Read Word

Block Read

Block Read

Block R/W

R/W Word

Read Word

Block R/W

Block R/W

6

30

Bit7

Bit7

Bit6

Bit6

Bit5

Bit5

Bit4

Bit4

Bit3

Bit3

Bit2

Bit2

Bit1

Bit1

Bit0

Bit0

High byte

-

-

-

-

-

EEPER

ADL_ON

INITIAL_
STATE

-

-

-

-

-

PFC OK

_

-

-

M S

/

Low byte

Low byte

-

-

-

OPERATION_INIT

PM_CTRL

DC_OK

Low byte
Bit 0  PM_CTRL: PMBus

Control Selection

Bit 1: DC_OK : Secondary DD output voltage status

Bit 2: P

_OK :

FC

Primary PFC status

Bit 0: M/S : Parallel mode status

Bit 1: 2

OPERATION_INIT :

OPERATION_INIT :

Initial Operational Behavior

0b00=

Power on with

0x00: OFF

0b01=

Power on with

0x80: ON(default)

0b10=

Power on with the last setting

0b11=

Not used

Note:

Unsupported settings display with

"0"

0=

Output voltage and current controlled by SVR/PV/PC (default)

0

TOO  LOW

=Secondary DD output voltage status

0=Primary PFC OFF or abnormal

0=Current device is Slave

1=

Output voltage, current and remote ON/OFF controlled by PMBus

(VOUT_TRIM IOUT_FAULT_LIMIT OPERATION)

1=Secondary DD output voltage status NORMAL

1=Primary PFC ON normally

1=Current device is Master

Definition of

Command BEh SYSTEM_CONFIG

:

Definition of

Command BFh SYSTEM_STATUS:

Bit 4  ADL_ON : Active dummy load control status

Bit 5  INITIAL_STATE : Device initialized status

0=Active dummy load off

0=In initialization status

1 Active dummy load

on

1=NOT in initialization status
Note: Unsupported settings display with "0"

6

Содержание SHP-10K-115

Страница 1: ...SHP 10K HV Series 10KW HVDC Power Supply Installation manual 3 3 wire wide input range High efficiency Intelligent Automate Telecom Industrial EV Security...

Страница 2: ...demanded by various industries Two types of cooling methods forced air and water cooling that can be working at ambient temperature up to 70 Moreover SHP 10K HV provides vast design flexibility by eq...

Страница 3: ...ion 5 1 Inrush Current Limiting 5 2 Power Factor Correction PFC 5 3 Output Voltage Adjustment 5 4 Output Current Adjustment 5 5 Parallel function 5 Remote Control 6 5 7 Alarm Signal Output 5 8 Auxilia...

Страница 4: ...range n Please do not stack any object on the unit n The safety protection level of this supply is class I The Frame Ground of the unit must be well connected to PE Protective Earth n The device shou...

Страница 5: ...axes 40A 400VAC 65A 480VAC 6 5mA peak 530VAC 100 105 of rated current Protection type Constant current limiting unit will shutdown after 5 sec re power on to recover 60 5 69 1V Protection type Shut do...

Страница 6: ...lerance includes set up tolerance line regulation and load regulation 4 Derating may be needed under low input voltages Please check the derating curve for more details 5 Additional EMI filter is need...

Страница 7: ...ical specification Forced Air Cooling Blank type Mounting Instruction Mounting Screw Mounting Surface Chassis of SHP 10K Hole No Recommended Screw Size MAX Penetration Depth L Recommended mounting tor...

Страница 8: ...Normal Mounting The B type is suggested mounting on horizontal surfaces lank 3 1 2 Mounting on a Water Cooled Plate A L type with a water cooled plate for heat dissipation it is suggested mount the su...

Страница 9: ...cification to receive the maximum length of mounting screw C Mounting methods other than chapter 3 1 or operate under high ambient temperature may increase the internal component temperature and will...

Страница 10: ...LOAD SHP 10K CORE AC I P DC O P Cx Cx Cy R1 R2 L L L L L3 L2 L3 PE L2 PE LOAD LINE A Schematic FREQ MHz FREQ MHz 0 01 10 20 70 5 13 0 05 20 47 93 7 16 0 10 30 61 111 47 0 15 50 66 136 58 0 50 60 100...

Страница 11: ...nts signal rebound for differential signals of CAN bus and Modbus 4 16 4 1 2 Pin Assignment of CN53 2 1 10 9 Pin No 1 2 3 4 5 6 7 8 9 10 Function V Signal PV PC DB DA Description Negative output volta...

Страница 12: ...e signal return is isolated from the output terminals V V For PMBus model Serial Clock used in the PMBus interface Note For PMBus model Serial Clock used in the PMBus interface Note For CANBus model D...

Страница 13: ...rcing current is 10mA and only for output Note The maximum sourcing current is 10mA and only for output Note The maximum sourcing current is 10mA and only for output Note The maximum sourcing current...

Страница 14: ...tration below 5 1 3 SVR Figure 5 1 ON OFF 1 2 3 coarse tune fine tune DIP SW1 5 22 A Have the DIP switch position 3 set as B Connect output of the external DC source to PV and as V signal shown in Fig...

Страница 15: ...5 5 E Covered by over temperature protection auto de rating function works under operation either in PC mode or under control by communication protocol T1 Typ Maximum ambient temperature of full load...

Страница 16: ...owing equation Maximum output current at parallel operation Rated current per unit Number of unit 0 95 When the total output current is less than 5 of the total rated current or say 5 of Rated current...

Страница 17: ...nd mode data Each SHP 10K unit should have their unique and own device address to communicate over the PMBus 7 bit address setting is used to assign advice address shown in the description below A0 A2...

Страница 18: ...t reading value format linear N 5 STATUS_MFR_SPECIFIC STATUS_FANS_1_2 READ_VIN READ_VIN READ_VIN READ_IIN READ_IIN READ_IIN READ_VOUT READ_IOUT Read Word Read Word Read Word Read Word Read Word Read W...

Страница 19: ...READ_FAN_SPEED_1 READ_FAN_SPEED_2 6 Physical layer specification This protocol follows CAN ISO 11898 with Baud rate of 250Kbps Data Frame This protocol es Extended CAN 29 bit identifier frame format o...

Страница 20: ...11 MFR_DATE_B0B5 MFR_SERIAL_B0B5 MFR_SERIAL_B6B11 MFR_MODEL_B6B11 MFR_REVISION_B0B5 MFR_LOCATION_B0B2 MFR_MODEL_B0B5 READ_VIN_TR READ_ IN_ I R READ_ IN_ I S READ_ IN_ I T READ_VOUT READ_IOUT READ_ TEM...

Страница 21: ...value is 0x0960 hexadecimal 2400 decimal then VDC_real 2400 0 01 24 00V 6 36 MFR_MODEL_B0B5 0x0082 is the first 6 codes of the manufacturer s model name ASCII MFR_MODEL_B6B11 0x0083 is the last 6 code...

Страница 22: ...t7 Bit0 Reserved Bit3 Bit3 Bit3 Bit3 Bit2 Bit2 Bit2 Bit2 Bit1 Bit1 Bit1 Bit1 Bit0 Bit0 Bit0 Bit0 byte4 5 byte3 byte2 byte1 byte0 byte0 Bit 0 3 VOUT Factor The factor of output voltage 0x 0 Output volt...

Страница 23: ...l status 0 The output voltage current defined by control over SVR PV PC 1 The output voltage current ON OFF control defined by control over CANBus VOUT_SET IOUT_SET OPERATION Bit 1 2 OPERATION_INIT Pr...

Страница 24: ...code 1byte what The function code is used to tell the slave kind of action to perform Data N bytes For data exchange contents and data length are dependent on different function codes Error Check 2by...

Страница 25: ...0C3 0x00C4 Note The conversion of setting and reading values is defined as following Actual value Communication reading value Factor F x value Among them Factor needs to refer to the definition of SCA...

Страница 26: ...0 0x41 0x50 0x20 0x2D 0x4E 0x2D 0x20 0x32 0x57 0x33 0x20 0x34 0x45 0x35 0x20 0x20 MFR_ID_B0B5 0x0080 0x0082 is the first 6 codes of the manufacturer s name ASCII MFR_ID_B6B11 0x0083 0x0085 is the last...

Страница 27: ...te 1 Byte 7 Byte 2 Byte 8 Byte 3 Byte 9 Byte 4 Byte 10 Byte 5 Byte 11 6 48 SCALING_FACTOR 0x00C0 Bit7 Bit7 Bit7 Bit7 Bit6 Bit6 Bit6 Bit6 Bit5 Bit5 Bit5 Bit5 Reserved Reserved FAN_SPEED Factor IOUT Fac...

Страница 28: ...DD output voltage status TOO LOW 1 Secondary DD output voltage status NORMAL Bit 2 PFC_OK Primary PFC status 0 Primary PFC OFF or abnormal 1 Primary PFC ON normally Bit 4 ADL_ON Active dummy load cont...

Страница 29: ...FFFF 0x7DEC 6 3 7 2 Read Input Register FC 04 The request message specifies the starting register and quantity of registers to be read For example The master requests the content of analog input regis...

Страница 30: ...8A 40 110 N A 0 57 6V 24 57 6V 31 2 6V 0 165A 30 153 7A 0 138V 57 5 138V 57 5 23V 0 95 7A 17 4 89 1A 0 260V 108 260V 122 30V 0 50 8A 9 2 47 4A 0 400V 167 400V 213 20V 0 33A 6 30 7A Display value rang...

Страница 31: ...7 1 1 Over Temperature Protection OTP and T Alarm 7 1 2 AC Fail 7 4 1 Short Circuit Protection 7 3 1 FAN FAIL T ALARM to GND AUX TTL AC OK to GND AUX TTL FAN FAIL to GND AUX TTL Condition Condition C...

Страница 32: ...not replace parts or any form of modification to the product in order to keep the warranty effectively MEAN WELL possesses the right to adjust the content of this manual Please refer to the latest ve...

Страница 33: ...No 28 Wuquan 3rd Rd Wugu Dist New Taipei City 248 Taiwan...