![Mean Well CMU2C Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/mean-well/cmu2c/cmu2c_installation-manual_1757957037.webp)
67
5
0x0200
+0x30*N
0x0201
+0x30*N
0x0202
+0x30*N
0x0203
+0x30*N
0x0204
+0x30*N
0x0205
+0x30*N
0x30*N
0x30*N
0x30*N
0x30*N
0x30*N
0x30*N
0x30*N
0x30*N
0x30*N
~
~
~
~
~
~
~
~
~
0x30*N
0x30*N
0x30*N
0x2F*N
0x30*N
0x30*N
0x30*N
0x30*N
0x30*N
Command
Name
FAULT_
STATUS
READ_
VOUT
READ_IOUT
READ_
TEMPERATURE_1
READ_FAN_
SPEED_1
READ_FAN_
SPEED_2
MFR_ID_
B0B5
MFR_DATE_
B0B5
MFR_SERIAL_
B0B5
MFR_SERIAL_
B6B11
MFR_ID_
B6B11
MFR_MODEL_
B0B5
MFR_MODEL_
B6B11
MFR_REVISION_
B0B5
MFR_LOCATION_
B0B2
Read fault status of a
single PSU
Read output voltage
of a single PSU
Read output current
of a single PSU
Read internal
temperature of a
single PSU
Read fan speed of the
fan 1 of a single PSU
Read fan speed of the
fan
of a single PSU
2
Read manufacturer's
name of a single PSU
Read manufacturer's
name of a single PSU
Read manufacturer's
model name of a
single PSU
Read manufacturer's
model name of a
single PSU
Read firmware
revision of a single
PSU
Read manufacturer's
factory location of a
single PSU
Read manufacture
date of a single PSU
Read product serial
number of a single
PSU
Read product serial
number of a single
PSU
0x03
0x04
0x04
0x04
0x04
0x04
0x03
0x03
0x03
0x03
0x03
0x03
0x03
0x03
0x03
2
2
2
2
2
2
6
6
6
6
6
4
6
6
6
# of data
Bytes
Description
Status Reading of PSU (PSU#0 - 47) (address range:0x0200~
0x0229):
※
PSU number, range: 0 – 47, 48 units in total.
N means
※
Maximum register quantity for a single PSU is 48.
Register
Addresses
Supported
Function Codes
68
5
0x6000
High byte
High byte
High byte
High byte
PSU#0~15
PSU#
~
16 31
PSU#
~
32 47
Relay1~ Relay4(0x0030 - 0x0033) Setting:
Low byte
Low byte
Low byte
Low byte
Bit7
Bit7
Bit7
Bit7
Bit6
Bit6
Bit6
Bit6
Bit5
Bit5
Bit5
Bit5
Bit4
Bit4
Bit4
Bit4
Bit3
Bit3
Bit3
Bit3
Bit2
Bit2
Bit2
Bit2
Bit1
Bit1
Bit1
Bit1
Bit0
Bit0
Bit0
Bit0
PSU#15
PSU#31
PSU#47
---
---
---
---
PSU#14
PSU#30
PSU#46
PSU#13
PSU#29
PSU#45
PSU#12
PSU#28
PSU#44
PSU#11
PSU#27
PSU#43
PSU#10
PSU#26
PSU#42
PSU#9
PSU#25
PSU#41
PSU#8
PSU#24
PSU#40
Source
Delay
PSU#7
PSU#23
PSU#39
Trigger
PSU#6
PSU#22
PSU#38
PSU#5
PSU#21
PSU#37
PSU#4
PSU#20
PSU#36
PSU#3
PSU#19
PSU#35
PSU#2
PSU#18
PSU#34
PSU#1
PSU#17
PSU#33
PSU#0
PSU#16
PSU#32
~
0x7F3F
Command
Name
Event log #1
~
Event log
#8000
Read Event log #1
Read Event log
#8000
~
0x64
~
0x64
62
~
62
# of data
Bytes
Description
Status Reading of Event Log (address range:0x6000~0x07F3F):
※
N means No. of Event log, range: 0-7999, 8000 data in total
OPERATION (PSU#0~15/ PSU#16~31/ PSU#32~47)
(0x0001~0x
3) on/off Setting:
000
The tables below indicate data position for each PSU. When the
bit of a PSU is
meaning the PSU is off;
1
means the
“0”,
“ ”
PSU is on. For example: data for PSU#0~15 is 0x0001, meaning
PSU#0 is on and the rest of PSU#1 - #15 are off.
Register
Addresses
Supported
Function Codes