![Mean Well CMU2C Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/mean-well/cmu2c/cmu2c_installation-manual_1757957030.webp)
53
5.2.6.2 Output adj.
N
: You cannot turn on/off PSUs no onlie.
ote
t
5.2.6.3 Digital/Relay
Output adj. page can be used to set output voltage and current
and displays their adjustable range.
Click the red mark above to adjust output voltage. Click APPLY to
set a desired value after adjustment.
Click the blue mark below to adjust output current. Click APPLY
to set a desired value after adjustment.
This page is used to set functions of the digital I/O channels
and relays.
l
Digital Output
Each digital output channel can flexibly set a source, a
trigger definition, an action and a delay.
5
54
After setting, click to write your new parameters. Please
refer to the table below for detailed triggering functions.
Source:
Alarm, PSU or digital input channels are available to be selected.
After selection, the corresponding trigger conditions will appear.
For instance: trigger definitions will move to relevant protection
options for the rack powers when alarm is selected.
Trigger definitions:
(1)Alarm: rigger the output channel when one of the supplies
T
meets alarm conditions, such as OVP, OLP, short circuit or
any of the protections (default).
(2)PSU: I. PSU ON: rigger the output channel if one of the
T
supplies is running
II. PSU OFF: rigger the output channel if one of the
T
supplies is remote off or in alarm conditions.
III. PSU OFF: rigger the output channel if all of the
T
supplies are disconnect.
(3)DI CH1 CH5(digital input channels): rigger the output
–
T
channel according to condition of the selected input
channel.
APPLY
SOURCE
TRIGGER
Any (default),
OVP, OLP, Short,
OTP, AC-Fail,
Fan Lock
Alarm (default)
On, Off
PSU
High, Low
DI CH1 - DI CH5
ACTIVE
High (default),
Low
DELAY
Immed.(default)、
1Sec、5Sec、10Sec、
30Sec、1~10Min
5