3 Communication objects
3.1 Standard settings of the communication objects
The following table shows the standard settings for the communication objects:
Standard settings
–
Buttons
No.
Name
Object function
Length
C R W T U
0
F1:
F1/2:
Switch
1 Bit
X
X
0
F1:
F1/2:
Dimming On/Off
1 Bit
X
X
0
F1:
F1/2:
Blinds Up/Down
1 Bit
X
X
0
F1:
Toggle
1 Bit
X
X
0
F1:
Send status
1 Bit
X
X
0
F1:
F1/2:
HSV control On/Off
1 Bit
X
X
0
F1:
F1/2:
Forcible control
2 Bit
X
X
0
F1:
F1/2:
Percent value
Decimal value
Scene
1 Byte
X
X
0
F1:
F1/2:
Temperature value
Colour temperature
Brightness value
2 Byte
X
X
0
F1:
F1/2:
RGB value
HSV value
3 Byte
X
X
0
F1/2:
Setpoint shift
1 Bit
1 Byte
2 Byte
X
X
0
F1/2:
Basic Comfort setpoint
2 Byte
X
X
0
F1:
F1/2:
Mode selection (HVAC Mode)
1 Byte
X
X
0
F1 short:
F1/2 short:
Switch
1 Bit
X
X
0
F1 short:
F1/2 short:
Toggle
1 Bit
X
X
0
F1 short:
F1/2 short:
Forcible control
2 Bit
X
X
0
F1 short:
F1/2 short:
Percent value
Decimal value
Scene
1 Byte
X
X