background image

Installation, Service and Warranty Policy

IM 422-4 / Page 16 (Rev. 5/99)

One-Year Warranty of Entire Conditioner
AAF–McQuay Incorporated, hereinafter referred to as the “Com-
pany,” warrants to the original owner that each entire Incremental
Comfort Conditioner is free from defects in material and work-
manship. Any part or portion thereof which becomes defective
under normal use during the period of this warranty will be re-
paired or replaced provided the Company’s examination shall
prove to its satisfaction that the part was or became defective
under normal use. This warranty contemplates that first year
maintenance labor was arranged for with the installer or other-
wise at the time the conditioner was purchased or installed. The
Company’s examination shall prove to its satisfaction that the
part was or became defective under normal use. This warranty
contemplates that first year maintenance labor was arranged for
with the installer or otherwise at the time the conditioner was
purchased or installed. The Company’s obligations under this
warranty are limited to: (a) repairing the defective part or (b) fur-
nishing a replacement part provided the defective part is returned
to the factory, transportation charges prepaid. No reimbursement
will be made for expenses incurred in making field adjustments
or replacements unless specifically authorized in writing by the
Company.

This warranty constitutes the buyer’s sole remedy. It is

given in lieu of all other warranties. There is no implied war-
ranty of merchantability or fitness for a particular purpose.
In no event and under no circumstance shall the Company
be liable for incidental or consequential damages, whether
the theory be breach of this or any other warranty, negli-
gence, or strict tort.

No person (including any agent, salesman, dealer or

distributor) has authority to expand the Company’s obligation be-
yond the terms of this express warranty, or to state that the per-
formance of the product is other than that published by the
Company.

One-Year Refrigeration Circuit Warranty
Hermetically sealed motor-compressor assemblies and all
components of refrigeration circuits not readily separable there-
from are warranted to the original owner for one (1) year. Refrig-
erating circuits consist of the motor-compressor assembly,
evaporator coil, condenser coil and interconnecting tubing.
Repairs under this warranty will be made at the Company’s
expense provided that the refrigeration circuit is delivered, without
shipping damage, transportation prepaid to the factory or to a
factory designated repair station, at the Company’s option. This
one-year warranty does not include any other parts of the
equipment such as filters, capacitors, protective devices, or wiring.
The Company is not obligated under this warranty for field labor
such as service for inspection, removing, packing and/or
re-installing the refrigeration circuit, nor for return transportation
charges.

General Conditions
The above warranties are void if the Company’s equipment has
been damaged, misused, subjected to abnormal use or service
or its serial number has been altered, defaced or removed, or
payment for the equipment is in default. The Company is not
responsible for service to correct conditions due to misapplication,
improper installation, inadequate wiring, incorrect voltage condi-
tions or unauthorized opening of the refrigeration circuit, nor for
consequential damages. In case the Company’s equipment is
installed in conjunction with cabinets, grilles, louvers, controls or
other parts manufactured by others, these warranties shall apply
only to the Company’s manufactured portion of the equipment.
The conditions of the warranty plan are effective for eighteen
(18) months from date of factor y shipment. The
Company reserves the right to make a handling and inspection
charge in the case  of parts or equipment improperly returned as
defective and/or as being in warranty.

AAF–McQuay Incorporated

4900 Technology Park Boulevard, Auburn, New York 13021-9030 USA (315) 253-2771

Printed on recycled paper containing at least 10% post-consumer recycled material.

Содержание 106018561

Страница 1: ...McQuay Incorporated Incremental Comfort Conditioners Suite II With Top Mounted Hydronic Heat Section Installation Maintenance Data Group PTAC Part No 106018561 Date May 1999 IM 422 4 Page 1 Rev 5 99...

Страница 2: ...installer exercise caution This equipment is to be installed only by an experienced installation company which employs trained personnel Inspection When the equipment is received all items should be c...

Страница 3: ...Piping Rough in Typ R H L H 3 76mm Min 3 76mm Kickplate Removable Front 7 8 22mm Wall Thickness C A 11 4 32mm 27 8 67mm 16 406mm B 91 8 232mm 51 2 140mm 7 8 22mm 15 8 41mm 15 16 33mm 3 76mm Min Kickp...

Страница 4: ...uctions For panel wall and thin wall construction it is recommended that the optional top angle be used and the wall sleeve be supplied with a turned down flange see Figure 3 The recommended procedure...

Страница 5: ...nd the finished wall surface This is to accommodate the heat section and room cabinet The center of gravity is 103 4 273mm from the rear face of the standard wall sleeve If no subbase is being employe...

Страница 6: ...the brickstop contacts the exterior bricks as illustrated below If a brickstop is not used slide the wall sleeve in the wall so that it extends into the room a minimum of 11 8 29mm beyond the finishe...

Страница 7: ...supplied and pipe it according to the illustration Install valve and other accessories including air vents steam traps stop balance valves etc as specified by the design engIneer 5 For valve installed...

Страница 8: ...the condenser coil cover 8 If louver has not been previously installed connect to wall sleeve as described above 9 If louver is supplied by others as illustrated in Figure 4 page 5 be sure to install...

Страница 9: ...the hold down screw 4 Screw the cabinet to the wall using the screws provided There are two 2 screw holes provided on each side located on the inner flanges of the room cabinet 5 Loosen the four 4 win...

Страница 10: ...ld provide uninterrupted service for many years Scheduled maintenance of this equipment as described below is the key to the equipment s longevity 1 Air filters must be cleaned at regular intervals Tw...

Страница 11: ...0 Units Cooling Chassis 1 Compressor Overload Device 1 Compressor Running Capacitor 1 Evaporator Fan Motor 1 Condenser Fan Motor 1 Pushbutton Switch 2 Damper Switch 2 Thermostat 2 Knob for Thermostat...

Страница 12: ...nly TROUBLE CAUSE CURE 1 Blowers won t operate on COOL 2 Blowers operate on COOL but compressor doesn t start 3 Blowers run on COOL and compressor starts but stops after a short interval 4 Blowers run...

Страница 13: ...or c Align blower assembly and tighten nuts d Noise will disappear after equipment runs awhile e Make necessary adjustments to components f Check for proper adjustment Apply silicone oil or grease to...

Страница 14: ...IM 422 4 Page 14 Rev 5 99 Wiring Diagram Standard Manual Changeover Control Hydronic Heat With Normally Open Valve...

Страница 15: ...IM 422 4 Page 15 Rev 5 99 Wiring Diagram Standard Manual Changeover Control Hydronic Heat With Normally Closed Valve...

Страница 16: ...of the product is other than that published by the Company One Year Refrigeration Circuit Warranty Hermetically sealed motor compressor assemblies and all components of refrigeration circuits not read...

Отзывы: