Page 30
SMS programming and control
System Status Examples [**][UUUU][S][##]
System Status
Status = **1111S##
Firmware version
iRIS8 F/W: V7.82
iRIS8 F/W: V7.82
iRIS8 F/W: V7.82
Arm/Disarm Status
System Status Disarmed
System Status Full Armed
System in ALARM, Zones 2
PSTN Status
PSTN OK
PSTN Failed
PSTN Disabled
AC Power
AC Power OK
AC Power Failed
AC Power Not Connected
Battery
Battery
OK Battery
Low
Battery
OK
Isolates
Zones Isolated NONE
Zones Isolated 02,08
Zones Isolated 03
GSM Signal/Reg
Signal Strength 100% (31)
Signal Strength Excellent (28) Signal Strength Very Poor (4)
Example SMS’s received….
*1111S##
;Invalid Command
( only 1 asterisk )
**1112S##
;Invalid User Code
( 1112 is not programmed in the panel )
**1111x##
;Invalid Command
( x is an invalid command )
**1111S ##
;Invalid User Cmd Format
( has a space after the S command )
**1111A##
;System Armed by User 1
**1111A##
;System Already Armed
**1111P##
;System Partial Armed by User 1
**1111P##
;System Already Partial Armed
**1111d##
;System Disarmed by User 1
**1111a##
;System Not Armed, Zones 6 Open
(assuming zone 6 is open )
**111105t##
;PGM Output Not Programmed
( Function 80 isnt programmed for SMS control )
**111105t##
;PGM Output On
**111105t##
;PGM Output Off
Содержание iRIS8+
Страница 1: ......