EXTender
TM
7000 Installation Guide
Page 67
2.
Set the
Enabled
parameter to
Yes
.
3.
Set the
Mode
parameter to
PRI
.
4.
Set the
Node Type
parameter to
User
so that the T1/PRI port will be in User Mode.
5.
Set the
Switch Type
,
Line Code
,
and
Framing
parameters with values provided by the Telco (CO)/
PBX Administrator.
6.
Select a value for the
Line Build Out
parameter to attenuate the signal before it leaves the EXTender
7000. Use a value recommended by the Telco (CO) or PBX Administrator.
7.
Use the arrow keys to access the DS0_Default Channel Setup menu, as shown below:
MI Path
Configuration->WAN->T1/PRI_Port(WAN3)->T1/PRI_Port_2->
Channel Setup->DS0_Default
The following menu appears:
Figure 4-20: DS0_Default Channel Setup
8.
Set the
Enabled
parameter to
Yes
.
9.
Set the
Direction
parameter to
Both
. This parameter indicates the direction data will travel on the DS0
channel. The value
Both
means the channel will handle both inbound and outbound traffic.
10. Enter 80 into the
Services
parameter. This parameter enables you to select the services you wish to
use to connect to the CO/PBX. The value 80 assigns T1/PRI Voice Service to all DS0 channels.
11. Set the
Connect Type
parameter to
Dialup
.
Setting the Local Trunk Parameters
You must identify one of the MCK T1/PRI ports as the Local Trunk port.
1.
Access the Local Trunk menu using the following path:
MI Path
Configuration->Services->Local_Trunk
This menu has a single parameter:
T1/PRI Port
.
2.
Set this parameter to T1/PRI_Port2.
Set the Local Dialing Parameters
1.
For each remote telephone, follow the steps detailed in “Set the Local Dialing Parameters on page’ 72.
These parameters must be set for each telephone port.
2.
When finished, press the
←
key to accept changes and go back to the Configuration Menu
.
3.
Press the
↓
key to the
Save
parameter.
Содержание EXTender 7000
Страница 2: ......
Страница 11: ...EXTenderTM 7000 Installation Guide Page 11 ...
Страница 12: ...EXTenderTM 7000 Installation Guide Page 12 ...
Страница 75: ...EXTenderTM 7000 Installation Guide Page 75 ...
Страница 83: ...EXTenderTM 7000 Installation Guide Page 83 ...